![background image](http://html.mh-extra.com/html/smc-networks/lecpa-series/lecpa-series_operation-manual_1299839089.webp)
- 88 -
Appendix 1.2 LEF
series
setting value
LEFS Step data default
Model
LEFS16
LEFS25
LEFS32
LEFS40
Lead [mm]
10
5
20
12
6
24
16
8
30
20
10
S
tep
da
ta d
efa
ul
t
No.
0
0
0
0
Movement MOD
ABS
ABS
ABS
ABS
S
pe
ed
S
tr
ok
to 500
500
250
1000
500
250
1200
500
250
500
500
250
501-600
-
-
900
500
250
1200
500
250
500
500
250
601-700
-
-
630
420
230
930
500
250
500
500
250
701-800
-
-
550
330
180
750
500
250
500
500
250
801-900
-
-
-
-
-
610
410
200
500
500
250
901-1000
-
-
-
-
-
500
340
170
500
500
250
1001-1100
-
-
-
-
-
-
-
-
500
440
220
1101-1200
-
-
-
-
-
-
-
-
500
380
190
Position
0.00
0.00
0.00
0.00
Acceleration
3000
3000
3000
3000
Deceleration
3000
3000
3000
3000
Pushing force
100
100
100
100
Trigger LV
100
100
100
100
Pushing speed
30
30
30
30
Moving force
100
100
100
100
Area1
0.00
0.00
0.00
0.00
Area2
0.00
0.00
0.00
0.00
In position
0.50
0.50
0.50
0.50