![background image](http://html.mh-extra.com/html/smc-networks/lecpa-series/lecpa-series_operation-manual_1299839040.webp)
- 39 -
7.2 Basic parameter
The basic parameter is the data defining the driver operating conditions, the electric actuator condition,
and other conditions.
(1) Details of basic parameter
Activation:“XX” = Become effective just after recorded into the driver
“X” = Become effective after restarting the driver
“-“ = The parameter cannot be changed (fixed value)
Refer to
“Appendix 1. Default setting value per the electric actuator ”
Parameter
name
Range
Description
Acti-
vation
Controller ID
1 to 32
Identification number (axis) parameters of serial communications
are set.
X
IO pattern
Fixed value
This is the fixed value for this driver(It should not be changed).
-
ACC/ DEC
pattern
Fixed value
-
S-motion rate
Fixed value
-
Stroke (+)
*1)
This defines the positive (+) side limit of the position. (Unit: mm)
XX
Stroke (-)
*1)
This defines the negative (-) side limit of the position. (Unit: mm)
XX
Max speed
*1)
This defines the maximum limit of the speed (Unit: mm/s).
It should not be changed.
-
Max ACC/DEC
*1)
This defines the maximum limit of the ACC/DEC (Unit: mm/s
2
).
It should not be changed.
-
Def In position
*1)
This defines the range to activate the INP output when the electric
actuator is within it after the return to origin operation. (Unit: mm)
XX
ORIG offset
*1)
T
his defines the position of the electric actuator after the return to
origin operation. (Unit: mm)
● The ORIG offset is 0 (mm).
●
The ORIG offset is 100 (mm)
Caution
If the value for
the “ORIG offset” is changed, the “Stroke (+)”
and “Stroke (-)” of the
basic parameters should be checked again.
XX
Max force
*1)
The maximum force for the pushing operation (Unit: %).
XX
M
Electric actuator
The position recognized by the
driver after the return to the
origin operation (0mm).
The position is identified by the driver after the
return to the origin operation (100mm).
Between the left examples,
the electric actuator positions
are not different but the
reference point that the driver
recognizes will be changed
after the return to origin
operation.
M
Electric actuator