![SMC Networks LECPA Series Operation Manual Download Page 48](http://html.mh-extra.com/html/smc-networks/lecpa-series/lecpa-series_operation-manual_1299839048.webp)
- 47 -
● Photo coupler: ON
Inside of the driver
Positioning unit
NP+/PP+
NP-/PP-
● Photo coupler: OFF
Inside of the driver
Positioning unit
NP+/PP+
Line driver
NP-/PP-
[About the photo coupler ON/OFF in the LECPA pulse input circuit during differential input connection]
Command pulse
signa
High
Low
Line driver
A current is passing
through the circuit.
No current is in the
circuit.
Photo coupler: OFF
Photo coupler: ON
Command pulse
signa
Low
High