(4) Select "Drive" on the Parameter window. Change "Safe func set2" from "1000" to "0".
Select the "Download" button. The modified data is transmitted to the driver. Once downloaded, the
parameter set value for "Safe func set2" which was displayed in blue will now be displayed in black.
(5) Change Parameter protect to [1: Basic + Step data] on the screen, and then click on Download.
(6) Terminate the controller setting kit (LEC-W2), and then turn the driver power OFF. When the driver
power is turned ON next time, the automatic pulse reference detection will be OFF.
Caution
Do not set any values to "Safe func set2"other than those specified above.
Otherwise, malfunction can result.
Do not modify any parameters other than "Drive parameter (Safe func set2)", "Basic parameter",
and "ORIG".
Otherwise, malfunction can result.
Select the tag "Drive".
Change "Safe func set2"
parameter from "1000" to "0".
OFF : “0”
ON : ”1000”
Select download