OM_Axessor_CIT_V024_20170518_EN.pdf Operating
Manual
Page 16
Subject to change without prior notice
Axessor CIT
One time code mode
Via a activation procedure using the activation software (e.g. AS280-
INSW) the operating mode of the Axessor CIT can be switched to one of
the following one time code modes: ICS (Interactive Code System), OTC
(One Time Combination) or DM (Dual Mode ICS + OTC).
–
OTC
In OTC mode the Axessor CIT accepts a generated code from the code
dispatch centre (code dispatch centre with dispatch software) for a sin-
gle opening. This one time code is valid for an unlimited period of time,
but only for a single use. The user identifies himself at the lock with his
4 digits ID.
At the lock
Dispatcher software AS274
select user
select lock
generate code
insert ID
insert code
lock opens
lock closed again
close seal
insert in SW
Summary of Contents for Axessor CIT