OM_Axessor_CIT_V024_20170518_EN.pdf Operating
Manual
Page 72
Subject to change without prior notice
Axessor CIT
6.4.3 Menu
DELAY
6.4.3.1 Setting/Deactivating Time Delays - Submenus DELAY
1...4
Once a valid code is entered, the lock only opens after the configured time
delay has elapsed. A time delay can be set between 0 (deactivated, no
Time Delay) and 99 minutes. Four Time Delays can be programmed:
• Time Delay 1: valid for Master, Manager 1 and Users 11 ... 19
• Time Delay 2: valid for Manager 2 and Users 21 ... 29
• Time Delay 3: valid for Manager 3 and Users 31 ... 39
• Time Delay 4: valid for Manager 4 and Users 41 ... 49.
Authorization:
Master Code or Manager Code
1. Select the submenu „
DELAY 1
“, „
DELAY 2
“, „
DELAY 3
“ or „
DELAY 4
“.
2. Press
the
<ENTER>
key. The currently set Time Delay is displayed.
3. Use
the
<LEFT>
or
<RIGHT>
key to set the desired Time Delay (setting
range „00:00“ (deactivated, no Time Delay) to „99:00“ minutes).
Note!
• Upon delivery Time Delays are deactivated (set to „00:00“).
• The programmable maximum value of a Time Delay may be limited by the
minimum time gap between two Weekly Locking Periods (
Adding a Weekly
Locking Period on page 63)
• You can defi ne minutes of the Delay only. Seconds cannot be defi ned.
• Entering a Courier Code opens the lock without any Time Delay.
• Ex factory the Duress Time Delay in one time code mode is set to
99 minutes.
4. In the upcoming dialogue select „
YES
“ using the
<LEFT>
or
<RIGHT>
key, then press the
<ENTER>
key to confirm.
Summary of Contents for Axessor CIT