OM_Axessor_CIT_V024_20170518_EN.pdf Operating
Manual
Page 82
Subject to change without prior notice
Axessor CIT
6.4.4.3 Setting User Codes - Submenu USER
Authorization:
Master Code, respective Manager Code or
respective User Code
AS284-USBW or AS284-NETW Programming Software
• If the Manager Codes are defi ned as: „Manager can Cross Access User
Codes“, Manger can also modify User Codes of another User Group.
• User 41 can be defi ned as audit code. If set so, the user can get the audit of
the lock with the AS284-USBW or AS284-NETW software. The audit code
can‘t be used to open the lock and the message „DENIED“ will be displayed
(the user code 41 has to be entered within the software).
• User 42 can be defi ned as activation code. If set so, the user can activate the
lock for importing either into the OTM application AS274 or into the AS284-
NETW software. The activation code can‘t be used to open the lock and the
message „DENIED“ will be displayed (the user code 42 has to be entered
within the software AS280-INSW).
• User 45 and 46 can be defi ned to activate a relay output. If set so, user 45
and 46 can‘t be used to open the lock.
• User 47 can be defi ned as time code. If set so, the user has access to all
time functions e.g. time, date, weekly and holiday programs. The time code
can‘t be used to open the lock.
• The User Codes 48 and 49 can be defi ned as: „disabling/enabling the lock“.
Thereupon, User Codes 48 and 49 can no longer open the lock, they can
only disable/enable the lock. Entering the User Code 48 disables the lock
whereas entering the User Code 49 enables the lock.
1. Select the submenu „
USER
“.
2. Press
the
<ENTER>
key.
3. This step must be performed only, If programming mode was entered
with Master Code or a Manager Code: use the
<LEFT>
or
<RIGHT>
key
to select the User Code you wish to alter (User Codes already acti-
vated are displayed by „USED“ not activated codes are displayed by
„– – – –“).
Summary of Contents for Axessor CIT