Operating Manual 

OM_Axessor_CIT_V024_20170518_EN.pdf

Subject to change without prior notice 

Page 87

Axessor CIT

6.4.4.7  Deleting a code

Authorization: 

 Access Codes on page 43

1.  Select the Menu „

CODE

“.

 

2.   Press the 

<ENTER>

 key.

3. Use 

the 

<LEFT> 

or

 <RIGHT>

 key to select the 

code type

 (e.g. „User“) 

you wish to alter, then press the 

<ENTER>

 key.

 

4.   Use the 

<LEFT> 

or

 <RIGHT>

 key to select the 

Code

 (e.g. „User 11“) you 

wish to alter.

 

5.   Press the 

<DEL>

 key. You are asked whether you want to delete the 

code. 

 

6.   Select „

YES

“ (using the 

<LEFT> 

or

 <RIGHT>

 key), then press the 

<EN-

TER>

 key

7. Press 

the 

<ENTER>

 key to confirm the deletion. 

Note!

• The Master Code cannot be deleted.
• Upon deletion of a Manager Code the corresponding group of User Codes 

remain unchanged and will not be deleted.

Summary of Contents for Axessor CIT

Page 1: ......

Page 2: ...age 3 Axessor CIT System overview Electronic safe lock Axessor CIT 3 2 5 4 1 11 12 10 9 7 8 6 15 14 13 1 2 3 4 5 6 7 8 Ty pe P ar t N o S er ia l N o Ve rs io n C er ts A xe ss or X X X X X X X X X X X X X X X X X X X X X X X X xx xx x xx 2 0 0 8 V d S 16 18 19 17 21 24 28 22 23 26 25 27 29 20 ...

Page 3: ... 9 0 9 numeric keys 0 9 10 DEL key delete close lock 11 LCD liquid crystal display 12 Buzzer Lock 13 Lock housing 14 Terminal blocks Inputs Outputs 15 Pin for cable tie holder 16 Connecting socket X1 cable from input unit and X2 external power supply or cable from eBox 17 Warranty seal 18 Type label 19 VdS label protects spring bolt setting screw 20 External power supply option eBox Option 21 Powe...

Page 4: ...o the unit 12 2 4 Environment 12 3 Product overview 13 3 1 Product description 13 3 2 Field of application 15 3 3 Intended use 15 3 4 Operating modes of the Axessor CIT 15 3 5 System components 18 3 5 1 Axessor CIT lock 18 3 5 2 AS280 INSW activation software 18 3 5 3 AS284 USBW or AS284 NETW programming software 18 3 5 4 AS274 server management software 18 3 5 5 APHI Application Programming Hardw...

Page 5: ...5 7 8 Entry of the opening combination mode I OTC 38 5 7 9 Entry of the opening combination mode I ICS 38 5 7 10 The close seal is displayed mode I 39 5 7 11 Post access delay modes S and I 39 5 7 12 Opening time delay mode I 39 5 7 13 Opening time delay mode S 39 5 7 14 Confirmation after elapse of Time Delay mode S 40 5 7 15 Enter second code Dual Mode activated mode S 40 5 7 16 Penalty after wr...

Page 6: ... overview 57 6 3 Access rights 58 6 4 Programming 59 6 4 1 Menu TIME 59 6 4 1 1 Setting the time submenu TIME 59 6 4 1 2 Setting the time submenu DATE 60 6 4 1 3 Setting the time format submenu AM PM 61 6 4 1 4 Setting the daylight saving time submenu DST 61 6 4 2 Menu PROG 62 6 4 2 1 Activating an Immediate Time Lock Submenu IMM TL 62 6 4 2 2 Configuring Weekly Locking Periods Submenu WEEKLY 63 6...

Page 7: ...Y cit 78 6 4 3 10 Configuring the opening delay of OTM Duress Alarm Submenu DURESS cit 79 6 4 4 Menu CODE 80 6 4 4 1 Changing the Master Code Submenu MASTER 80 6 4 4 2 Setting Manager Codes Submenu MANAGER 81 6 4 4 3 Setting User Codes Submenu USER 82 6 4 4 4 Setting the Courier Code Submenu COURIER 84 6 4 4 5 Reset the whole Axessor CIT safe lock system to factory def aults Submenu SHELVE 85 6 4 ...

Page 8: ... 5 14 Enabling disabling Time Lock for OTM Submenu TL LOCK cit 96 6 4 5 15 Enabling disabling Non Return Time Delay Submenu NRTD cit 96 6 4 5 16 Display the current time Submenu TIME cit 97 7 Servicing 98 7 1 Cleaning 98 7 2 Replacing the batteries 98 7 3 Customer Service 99 7 4 Spare parts and accessories 100 8 Error messages 101 9 Technical data 104 9 1 Functions 104 9 2 Electronics 107 9 3 Mech...

Page 9: ... in this Operating Manual please contact your supplier They will be glad to assist you 1 2 Notes regarding the Operating Manual 1 2 1 Validity This Operating Manual describes the Axessor CIT electronic safe lock 1 2 2 Target group This Operating Manual addresses itself to well trained personnel which is in charge with the installation the commissioning the operation the ser vicing and the trouble ...

Page 10: ...ormation or point out specific details Requirement Indicates requirements that must be met for the execution activation modification or deletion of the described function These requirements must be met before proceeding AS284 USBW or AS284 NETW Programming Software Refers to the AS284 USBW or AS284 NETW Programming Software op tionally available which allows additional settings and functions 1 2 6...

Page 11: ...scope of this manual must be carried out only by qualified personnel authorised by the manufacturer It is assumed that all persons working with the Axessor CIT are familiar and comply with the appropriate regulations on work safety and the pre vention of accidents 2 3 Prohibited modifications to the unit Modifications on the Axessor CIT electronic safe lock are explicitly not recommended it may vo...

Page 12: ...SBW or AS284 NETW Programming Software optionally avail able This gives access to an even enhanced functionality and allows customer tailored solutions to almost every extent Unit configuration standard version In its standard version the Axessor CIT electronic safe lock is battery powered and consist of the input unit the lock and the connection cable The lock includes 2 inputs and 2 outputs assi...

Page 13: ...Box functions To set up and configure the Axessor CIT electronic safe lock for network integration AS280 INSW Installation software and the AS284 USBW or AS284 NETW Programming Software are required Local Area Network 10 100BaseT Ethernet Safe 1 Safe 2 Safe n PC with AS 284 NETW Programming Software Other devices 1 2 3 4 5 6 7 8 Type Part No Seria l No Versi on Certs Axes sor serie s XXXX XXXX XX ...

Page 14: ...ad of a mechanical combination or key lock Ap plicable regulations and standards have to be observed Enabling lock opening is only performed upon entry of one or several codes on the Input Unit The opening procedure can also be made depend ent on time functions and or external signals The Axessor CIT electronic safe lock may only be employed and operated in accordance with its intended use blockin...

Page 15: ...ive Code System OTC One Time Combination or DM Dual Mode ICS OTC OTC In OTC mode the Axessor CIT accepts a generated code from the code dispatch centre code dispatch centre with dispatch software for a sin gle opening This one time code is valid for an unlimited period of time but only for a single use The user identifies himself at the lock with his 4 digits ID At the lock Dispatcher software AS2...

Page 16: ... the opening procedure Mixed mode Additionally the so called mixed mode can be set via the activation soft ware The mixed mode combines the advantages of the bank mode and the one time code mode The switch between one time code mode to bank mode is done via the MODE key on the lock If the lock is in one time code mode Identif is shown in the display of the lock which prompts the user to enter the ...

Page 17: ...280 INSW activation software The AS280 INSW activation software for Windows operating systems is used to switch from standard mode to interactive mode ICS OTC or Dual mode and mixed mode Additionally the AS280 INSW Software is used for network installation 3 5 3 AS284 USBW or AS284 NETW programming software Basic settings for the lock such as the language time delays for open ing inputs and output...

Page 18: ...OCTITE 243 medium blue Removal of or damage to the VdS label Template Lock on page 3 item 19 voids VdS approval The lock must not be mounted directly behind lead throughs Clog or secure lead throughs correspondingly A suitable cover plate to protect the lock is available from your supplier 52x DPUL drilling protection plate 4 2 Unpacking and checking the delivery Unpack the delivery and check the ...

Page 19: ...xation bores 3 and 5 or 2 and 4 plus bore 1 recom mended Also mark one of the two bores 6 cable lead through Do so according to the illustration below or by using the template Template Input Unit on page 112 2 Drill the 3 fixation bores Ø3 2 x 14 mm and the cable lead through bore Ø10 mm Remove burrs Tap M4 threads into the 3 fixation bores 40 41 3 55 10 4 x M4 1 3 2 6 10 6 5 4 193 90 ...

Page 20: ...f the cover 1 at the battery com partment 2 at the housing Lift off the cover from the base plate then carefully remove the battery compartment 4 Fix the base plate with the enclosed special M4x12 flat head screws to the door The Input unit must be fixed to the door with at least two oppositely positioned screws The third screw pos 1 is recommended ...

Page 21: ... draw it towards the lock chamber 6 Mount battery compartment in place Then carefully lead the battery cable through strain relief guides of the battery compartment and the base plate Make sure not to squeeze the cable Finally check for free movability of the battery compartment Make sure the spiral cable lays flat when moving the battery compart ment i e the cable does not move in other direction...

Page 22: ...he cover on top of the base plate in an angle 90 8 Plug the battery cable into the 2 pole connector terminal and the con nection cable into the 6 pole connector terminal Check correct position of the plugs before connecting them Do not use excessive force to plug in but make sure that proper connection is given Battery Lock ...

Page 23: ...towards the lock chamber leave some spare loop Make sure that cables are not squeezed Check battery compartment for free movability carefully push the battery compartment into place then slide it out again 11 Fix the cover on the base plate using two M3x6 countersink screws 12 Check battery compartment for proper movability carefully push the battery compartment into place then slide it out again ...

Page 24: ...he 3 enclosed M6x10 screws equivalent Inch screws may be used instead Make sure that the screw heads rest on the base of the shouldered bore Make sure to keep the space underneath the lock free for a re locker system or the connection cable 4 If the lock is to be operated in spring bolt function remove the retainer screw B underneath the VdS label Be aware that this operating mode voids VdS approv...

Page 25: ...ion of the connector then carefully plug connection cable into one of the lock sockets X1 or X2 7 Secure the cable with the cable tie and carefully fix any excess cable max 5N max 1000N max 1000N max 1000N 1 2 3 4 5 6 7 8 11 5 15 2 x M4 13 25 2 7 8 Type Part No Serial No Version Certs AXXESSOR series XXXXXXXXXX XXXXX XXXXXX XXX xxxxx xx 2008 VdS 1 2 3 4 5 6 7 8 Ty pe P ar t N o S er ia l N o Ve rs...

Page 26: ...in 4 Confirm the error message by entering the current Master Code de fault 00123456 with the NUMERIC keys then press the ENTER key The lock opens and closes again after approx 6 seconds 5 Fix battery compartment with hexagon countersink screw Important If during wiring test the error message LINE OFF continuously appears the connection cable is either connected incorrectly or it was damaged durin...

Page 27: ...C 2A 50 VAC 0 5A with resistive load Relay with potential free working contacts NO normally open 3 4 Output 1 standard Duress alarm 5 6 Input 1 standard not assigned optional remote disabling or controlled disabling 12 VDC min 20mA 7 8 Input 2 standard not assigned optional Programmable with AS284 USBW or AS284 NETW Programming Software Do not apply any voltage poten tial free contact only Recomme...

Page 28: ...oor Contact Example of wiring several locks in a way that only one lock may be opened at the same time The following settings must be made with the AS284 USBW or AS284 NETW Programming Software in addition Output 2 bolt or motor open Input 1 Controlled disabling 1 2 3 4 5 6 7 8 1 2 3 45 6 78 1 2 3 45 6 78 1 2 3 45 6 78 GND 12V 20mA ...

Page 29: ...Remove the burrs and tap M6 threads into the bores 3 Mount eBox with the 2 enclosed M6x10 socket screws equivalent Inch screws may be used instead Connect cable 4 Verify correct position of the connector then carefully plug enclosed eBox connection cable into one of the eBox sockets and one of the lock sockets X1 or X2 93 5 106 5 27 27 A A 1 2 3 4 5 6 7 8 Ty pe P ar t N o S er ia l N o Ve rs io n ...

Page 30: ...nctions but not the eBox functions Terminal Description Capacity Remarks 2 4 6 8 10 12 16 14 18 20 1 3 5 7 9 11 15 13 17 19 OUT 3B OUT 4B OUT 5B OUT 6B OUT 7B IN 3 IN 5 IN 7 Power supply GND OUT 3A OUT 4A OUT 5A OUT 6A OUT 7A IN 4 IN 6 GND GND GND 7 mm Note the function of the Inputs and Outputs can be assigned with the optional AS284 USBW or AS284 NETW Programming Software 18 20 Power supply 9 VD...

Page 31: ...tandard not assigned 13 GND Input 6 standard not assigned 16 GND Input 7 standard not assigned Socket Description Capacity Remarks X3 RJ45 X4 X3 X4 Connection to lock only one lock can be connected to an eBox Enclosed connection cable must be used RJ45 Connection to Local Area Network 10 100Base T Ethernet Min CAT5 cable required Con necting network devices must have ground connection Wiring diagr...

Page 32: ...iring check after eBox installation After having finished the installation the Axessor CIT electronic safe lock is commissioned as follows 1 Perform wiring check Perform wiring check after lock installation on page 27 2 If eBox is connected after start initialization period the eBox LED must blink green twice every 2 seconds ...

Page 33: ...Programming Mode 7 RIGHT key directional key to navigate 8 INFO ESC key activate info display or escape go back to upper level 9 ENTER key enter confirm 10 Menu TIME to set time date 11 Menu PROG to program Locking Periods 12 Menu DELAY to program Time Delays 13 Menu CODE to modify codes 14 Menu MISC to access additional settings 15 Symbol Lock open unlocked or Lock closed locked 16 Symbol Replace...

Page 34: ...ny key to wake up the display if necessary The lock status ap pears e g LOCKED 2 Press the MODE key and key in a valid user code e g 12104453 us ing the NUMERIC keys an asterisks appears for every digit entered Press the ENTER key to confirm the Code The lock is in the Pro gramming mode for Immediate Time lock 3 Press ENTER twice 3 Use the LEFT or RIGHT key to set the duration in hours minutes The...

Page 35: ...n of the information menu can be queried in sequence Display language Battery condition in of the nominal capacity Last closing code of one time code mode OTM is active Opening counter if bank mode or mixed mode is active Serial number Wait 000 00 if set so Notes The display language can be changed within the information menu at any time by pressing the ENTER key even if the lock is closed The inf...

Page 36: ...onds OPEN Lock open AS284 USBW or AS284 NETW Programming Software Buzzer signal during OPEN lock open during WAIT Time delay and during CONF Confirmation window can be deactivated Buzzer volume may be set to high low or off 5 7 Status messages During operation the following status messages can be shown Status messages in bank mode standard mode are indicated with S status messages in interactive m...

Page 37: ...he current time is displayed It may only be opened by entering a valid code once the set Locking Period has elapsed 5 7 6 Holiday time lock modes S and I The lock is in a Holiday Locking Period and cannot be opened the current time is displayed It may only be opened by entering a valid code once the set Locking Period has elapsed 5 7 7 Ready for entry of combination mode I The lock is ready for op...

Page 38: ...seal 5 7 12 Opening time delay mode I In interactive mode the waiting period is not displayed during an opening time delay unlike the indication given in standard mode see below 5 7 13 Opening time delay mode S After entering a valid code to open the lock the set Time Delay starts counting the remaining time is displayed A BEEP signal is emitted every 60 seconds Once the counter has elapsed the en...

Page 39: ... the lock automatically returns to locked status once the counter reached 00 00 Notes If the DEL key is pressed the lock automatically returns to LOCKED status If Dual Mode is activated proceed as follows in the confirmation window Repeat two codes for confirmation whereby the sequence is irrelevant The codes must comply to the settings made with the AS284 USBW or AS284 NETW Programming Software a...

Page 40: ...upon malfunction of the external signal 5 7 18 Remote enabling mode S and I An external signal can be used to enable the lock to enter a code for opening When remote enabling is in effect this message will be displayed while the code input window is open Remote enabling takes place via an input impulse of at least 1 second Notes In case of failure of input signal device e g Alarming Interface brok...

Page 41: ...er Code or Manager Code In mode I a so called battery code is required 5 7 21 Connected with Programming Software mode S and I While the lock is connected to a computer via USB cable and a data exchange with the AS284 USBW or AS284 NETW Programming Software optionally available is in progress the opposite display is shown The Input Unit is not operative all keys are disabled While the lock is conn...

Page 42: ... x x x USER 11 1 1 x x x x x x USER 14 1 4 x x x x x x USER 12 1 2 x x x x x x USER 13 1 3 x x x x x x USER 18 1 8 x x x x x x USER 19 1 9 x x x x x x User Group 21 USER 16 1 6 x x x x x x USER 17 1 7 x x x x x x MANAGER 20 2 0 x x x x x x USER 25 2 5 x x x x x x USER 21 2 1 x x x x x x USER 24 2 4 x x x x x x USER 22 2 2 x x x x x x USER 23 2 3 x x x x x x USER 28 2 8 x x x x x x USER 29 2 9 x x ...

Page 43: ...ime lock If set so the Master code can open the lock even when in time lock period The Master Codes can be defined as can bypass Immediate time lock If set so the Master code can reset the immediate time lock even during an immediate time lock period The master code can override a Remote disabled signal or the disabled state while a Remote enabled signal is missing prevention of total lock out War...

Page 44: ...ing the lock Alteration of respective User Code AS284 USBW or AS284 NETW Programming Software The User Codes can be defined as can activate Immediate Time Lock If set so the submenu IMM TL is accessible for the users User 45 and 46 can be defined to activate a relay output If set so user 45 and 46 can t be used to open the lock User 47 can be defined as time code If set so the user has access to a...

Page 45: ...de With the shelve function you reset all codes param eters and data e g Locking Periods Time Delays etc to factory default settings Audit Trail opening counter and Time Date settings remain unchanged Note After resetting the lock is in bank mode again even if the lock has been acti vated in a one time code mode 5 8 4 Duress Code If the lock is connected to an external alarm system a silent duress...

Page 46: ... Manager 1 and Users 11 19 the second for Manager 2 and Users 21 29 the third for Manager 3 and Users 31 39 the fourth for Manager 4 and Users 41 49 The Duress Time Delays can be set independent longer or shorter of the normal Time Delays The counting of the Duress Time Delay is the same as set for the Time De lay count up count down or no count 5 8 4 2 Duress Code in interactive mode To trigger a...

Page 47: ...f necessary The lock status ap pears e g LOCKED 2 Key in the Code e g 11123456 using the NUMERIC keys an aster isks appears for every digit entered 3 Press the ENTER key to confirm the Code Note During code entry a possible observer can be diverted Only the first 7 and the last entered digit will be considered as code Enter your code as usual at least the first 7 digits and keep on adding any comb...

Page 48: ... is in process page 41 Active connection with the Programming Software page 42 During Non Return Time Delay page 41 5 10 1 Opening procedure in bank mode The Display switches off automatically after 1 minute without any key be ing pressed 1 Press any key to wake up the display if necessary The lock status ap pears 2 Key in the Code e g 11123456 using the NUMERIC keys an asterisk appears for every ...

Page 49: ...imer has elapsed another beep indicates the end of the opening delay After the opening delay has elapsed the confirmation window appears and the set confirmation time starts to count the remaining time within the opening must be confirmed is shown Enter the opening code as described in step 2 Press the ENTER key to confirm the Code If unit is set to Dual Mode enter second code as described above P...

Page 50: ...gers a duress alarm 3 The Request Code window appears showing ICS mode specific Re quest Code e g 654123 for 30 seconds The remaining time is shown within the opening code must be entered Forward the shown Request Code to the dispatch centre 4 Key in the Opening Code received from the dispatch centre e g 123456 using the NUMERIC keys Press the ENTER key twice to confirm the Code pressing the ENTER...

Page 51: ...ock status ap pears 2 Key in the 4 digit ID e g 3512 using the NUMERIC keys an asterisk appears for every digit entered Press the ENTER key twice to con firm the ID pressing the ENTER key once triggers a duress alarm 3 Key in the Opening Code received from the dispatch centre e g 123456 using the NUMERIC keys Press the ENTER key twice to confirm the Code pressing the ENTER key once triggers a dure...

Page 52: ...de The lock normally closes automatically when the bolt work is closed Note Depending on the safe design the closing procedure can be made dependent on additional factors Contact the supplier of the safe or consult section Installing the lock on page 25 5 11 2 Closing procedure in interactive mode The lock normally closes automatically when the bolt work is closed If the lock has closed a 6 digit ...

Page 53: ...e code you have entered AS284 USBW or AS284 NETW Programming Software If the setting Dual Manager for Programming Mode is activated two Manager codes must be entered to access the programming mode The content of the menu then comprises of the accessible content of both codes Important If no key is pressed in programming mode within 1 minute the unit returns automatically to normal operating mode a...

Page 54: ...ngs in the Programming Mode To modify an individual setting proceed as follows 1 Select the desired main setting in the menu e g TIME and press the ENTER key 2 Select the desired sub setting and modify it according to the instruc tions for the corresponding setting Programming on page 59 3 Confirm the setting with the ENTER key 4 In the upcoming save dialogue select YES using the LEFT or RIGHT key...

Page 55: ...out prior notice Axessor CIT 6 1 4 Exiting the Programming Mode Press repeatedly the DEL or INFO ESC key jumps to the next higher menu level to return to normal operating mode Important Any changes which have not been confirmed with the ENTER key and the message ACCEPTED will be lost ...

Page 56: ...ds Submenus IMM TL WEEKLY HOLIDAY TL INT TR FNC1 TR FNC2 TR FNC3 Menu DELAY configuring Time Delays Submenus DELAY 1 DELAY 2 DELAY 3 DELAY 4 CNF WIN NRTD HM D ALARM DUAL bank BLT OPN bank BLT OPN cit PROCTIM cit DELAY cit DURESS cit Menu CODE modifying codes Submenus MASTER MANAGER USER COURIER SHELVE Menu MISC accessing additional settings Submenus LANG RMT DIS VOLUME OPEN beep CNF WIN beep DELAY...

Page 57: ...er 2 Time Delay 2 Manager 3 Time Delay 3 Manager 4 Time Delay 4 Set Confirmation Window Change Master Code Master Code cannot be deleted Change Manager Code Delete Manager Code Respective User Codes will not be deleted Change Courier Code Delete Courier Code Delete User Codes Change User Code User can only change own code Employ Shelve Function Deny permit subordinated codes Entire group of User C...

Page 58: ...ME 6 4 1 1 Setting the time submenu TIME Authorization Master Code 1 Select the submenu TIME 2 Press the ENTER key The currently set time is displayed 3 Enter the time using the LEFT or RIGHT key to select the current hour Press the ENTER key to confirm and to go on to adjust the minutes using the LEFT or RIGHT key Confirm again by pressing the ENTER key Note If time format AM PM is activated Sett...

Page 59: ...m and moving to the day 4 Use the LEFT or RIGHT key to select the day Press the ENTER key to confirm and moving to the year 5 Use the LEFT or RIGHT key to select the year Press the ENTER key to confirm 6 In the upcoming save dialogue select YES using the LEFT or RIGHT key if necessary then press the ENTER key to save the setting The Message ACCEPTED appears shortly and the unit re turns to the sub...

Page 60: ... displayed in 12 Hour Format 1 00 12 59 with suffix AM ante meridiem before noon or PM post meridiem after noon With AM PM OFF the time is displayed in 24 Hour Format 00 00 23 59 4 Press the ENTER key to confirm the setting in the upcoming save dialogue 6 4 1 4 Setting the daylight saving time submenu DST Authorization Master Code 1 Select submenu DST 2 Press the ENTER key The automatic set daylig...

Page 61: ...mming Software Only if the Manager Codes are defined as can activate Immediate Time Lock this setting is available with Manager Codes Only if the User Codes are defined as can activate Immediate Time Lock this setting is available with User Codes 1 Select submenu IMM TL 2 Press the ENTER key 3 Use the LEFT or RIGHT key to set the duration in hours minutes the Immediate Time Lock should be active a...

Page 62: ...ayed 3 Press the ENTER key to enter a new period 4 Use the LEFT or RIGHT key to set the day and the time of the starting point of the Locking Period indicated by the lock closed symbol and the ENTER key for confirmation 5 Confirm with the ENTER key Note If the maximum of 35 Weekly Locking Periods are already defined upon press ing the ENTER key the display does not change react Note Time and day e...

Page 63: ...Weekly Locking Periods are saved in chronological order starting with Mon day The AS284 USBW or AS284 NETW can configure that time Lock applies for OTM codes as well 6 4 2 2 2 Modifying an existing Weekly Locking Period Proceed as described for adding a new Weekly Locking Period Adding a Weekly Locking Period on page 63 Instead of pressing the ENTER key in step 3 use the LEFT or RIGHT key to selec...

Page 64: ... any Holiday Locking Periods are already defined the count is displayed 3 Press the ENTER key to enter a new period 4 Use the LEFT or RIGHT key to set the day and the year of the starting point of the Holiday Locking Period indicated by the lock closed symbol and the ENTER key for confirmation Note If the maximum of 22 Holiday Locking Periods are already defined upon press ing the ENTER key the di...

Page 65: ...iday Locking Period every year If the end date of a yearly repeated Holiday Locking Period is to be last day of February it is recommended to set it to February 29th in order to include leap years as well 6 4 2 3 2 Modifying an existing Holiday Locking Period Proceed as described for adding a new Holiday Locking Period Adding a Holiday Locking Period on page 65 Instead of pressing the ENTER key in...

Page 66: ...enter a new Time Lock Interruption period Note If the maximum of 8 Time Lock Interruption Periods are already defined upon pressing the ENTER key the display does not change react 4 Use the LEFT or RIGHT key to set the month of the starting point of the Time Lock Interruption and the ENTER key for confirmation Repeat this to set the day and the year 5 Use the LEFT or RIGHT key to set the hour of t...

Page 67: ...e LEFT or RIGHT key to select the Time Lock Interrupting Period you wish to alter and overwrite it 6 4 2 4 3 Deleting an existing Time Lock interruption Period 1 Select submenu TL INT 2 Press the ENTER key 3 Use the LEFT or Right key to select the starting point of the Time Locking Interruption Period you wish to delete 4 Press the DEL key 5 In the upcoming delete dialogue select YES using the LEF...

Page 68: ...alid for Manager 3 and Users 31 39 Authorization Master Code 6 4 2 5 1 Adding a Time Related Function 1 Select submenu TR FNC1 TR FNC2 or TR FNC3 2 Press the ENTER key If any Time Related Functions are already defined the count is displayed 3 Press the ENTER key to enter a new Time Related Function Note If the maximum of 3 Time Related Functions are already defined upon pressing the ENTER key the ...

Page 69: ...ches it off during the defined period If Dual Mode is switched off it switches it on during the defined period select YES using the LEFT or RIGHT key then press the ENTER key 8 If the User Group needs to be disabled codes denied select YES us ing the LEFT or RIGHT key then press the ENTER key 8 If the Time Related Function shall apply not to all days a week switch Weekly to ON using the LEFT or RI...

Page 70: ...ng the ENTER key in step 3 use the LEFT or RIGHT key to select the Time Related Func tion and its parameter you wish to alter and overwrite it 6 4 2 5 3 Deleting an existing Time Related Function 1 Select submenu TR FNC1 TR FNC2 or TR FNC3 2 Press the ENTER key 3 Use the RIGHT key to select the starting point of the Time Locking Interruption Period you wish to delete 4 Press the DEL key 5 In the u...

Page 71: ...ation Master Code or Manager Code 1 Select the submenu DELAY 1 DELAY 2 DELAY 3 or DELAY 4 2 Press the ENTER key The currently set Time Delay is displayed 3 Use the LEFT or RIGHT key to set the desired Time Delay setting range 00 00 deactivated no Time Delay to 99 00 minutes Note Upon delivery Time Delays are deactivated set to 00 00 The programmable maximum value of a Time Delay may be limited by ...

Page 72: ...e Delay 2 valid for Manager 2 and Users 21 29 Duress Time Delay 3 valid for Manager 3 and Users 31 39 Duress Time Delay 4 valid for Manager 4 and Users 41 49 One Duress Time Delay can be configured for one time code mode The Duress Time Delays can be set independent longer or shorter of nor mal Time Delays It is also possible to suppress Time Delays with an external signal Exter nal connections at...

Page 73: ...es 1 Select the submenu CNF WIN 2 Press the ENTER key The currently set confirmation time is dis played 3 Use the LEFT or RIGHT key to set the desired confirmation time setting range 1 00 to 99 00 minutes Note Upon delivery Confirmation Window is set to 5 minutes The minimum value is 1 minute The programmable maximum value of a Time Delay may be limited by the minimum time gap between two Weekly L...

Page 74: ...Note Upon delivery Non Return Time Delay is set to 0 minutes The Non Return Time delay can be overridden with a code generated in One Time Mode AS274 This has to be enabled by the AS284 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 3 4 Configuring the opening delay of Duress Alarm Submenu D ALARM Once a duress code is entered the lock ope...

Page 75: ...Select the submenu DUAL bank 2 Press the ENTER key The currently set window is displayed minutes seconds 3 Use the LEFT or RIGHT key to set the desired window to enter the second opening code setting range 00 00 to 02 30 Note Upon delivery the opening window is set to 1 minutes 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 3 6 Configuring...

Page 76: ...Bolt Open Time for CIT mode Submenu BLT OPN cit Upon opening of the lock in CIT or OTC mode it will close automatically when the bolt open time has elapsed The automatic closing can be pre vented by connecting a door open contact or bolt work open contact Lock Input 2 on page 28 Authorization Master Code 1 Select the submenu BLT OPN cit 2 Press the ENTER key The currently bolt open time is display...

Page 77: ...ds 3 Use the LEFT or RIGHT key to set the desired window setting range 00 00 to 99 00 Note Upon delivery the window is set to 2 30 minutes 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 3 9 Setting OTM Time Delay Submenus DELAY cit Once a valid OTM code is entered the lock only opens after the configured time delay has elapsed A time delay...

Page 78: ...enu DURESS cit Once a OTM duress code is entered the lock opens after the OTM Duress Alarm opening delay time has elapsed Authorization Master Code 1 Select the submenu DURESS cit 2 Press the ENTER key The currently set duress opening time delay is displayed hours minutes 3 Use the LEFT or RIGHT key to set the desired duress opening time delay setting range 00 00 to 99 00 Note Ex factory the Dures...

Page 79: ...M D A M D A M D Respective Manager Code M A M D Respective User Codes M Courier Code M Legend A Activate M Modify D Delete 6 4 4 1 Changing the Master Code Submenu MASTER Authorization Master Code 1 Select the submenu MASTER 2 Press the ENTER key 3 Select YES using the LEFT or RIGHT key then press the EN TER key 4 Use the NUMERIC keys to enter the new code 5 Press the ENTER key to confirm 6 CONFIR...

Page 80: ...HT key to select the Manager Code you wish to alter Manager Codes already activated are displayed by USED not activated codes are displayed by 4 Press the ENTER key If you have selected an already activated code you are asked whether or not you want to modify the code 5 Select YES using the LEFT or RIGHT key then press the EN TER key 6 Use the NUMERIC keys to enter the new code 7 Press the ENTER k...

Page 81: ...TW software The activation code can t be used to open the lock and the message DENIED will be displayed the user code 42 has to be entered within the software AS280 INSW User 45 and 46 can be defined to activate a relay output If set so user 45 and 46 can t be used to open the lock User 47 can be defined as time code If set so the user has access to all time functions e g time date weekly and holi...

Page 82: ...ode you are asked whether or not you want to modify the code 5 Select YES using the LEFT or RIGHT key then press the EN TER key 6 Use the NUMERIC keys to enter the new code 7 Press the ENTER key to confirm 8 CONFIRM is displayed shortly to prompt you to enter the same code again for confirmation Use the NUMERIC keys to enter the same code again 9 Press the ENTER key to confirm ...

Page 83: ...cated with USED a Courier Code not activated is indicated by Press the ENTER key If the Courier Code is already activated you are asked whether or not you want to modify the code 4 Select YES using the LEFT or RIGHT key then press the EN TER key 5 Use the NUMERIC keys to enter the new code 6 Press the ENTER key to confirm 7 CONFIRM is displayed shortly to prompt you to enter the same code again fo...

Page 84: ...nputs outputs eBox settings and network data etc to factory set values Time date opening counter and Audit Trail will remain unchanged Before continuing be aware that all data will be lost Saving data with AS284 USBW or AS284 NETW Programming Software prior to shelving is recommended Take note that codes cannot be saved Authorization Master Code 1 Select the submenu SHELVE 2 Press the ENTER key 3 ...

Page 85: ... LEFT or RIGHT key to select the code type e g User you wish to alter Press the ENTER key Use the LEFT or RIGHT key to select the Code e g User 11 you wish to alter 4 Press the ENTER key You are asked whether or not you want to modify the code 5 Select YES using the LEFT or RIGHT key then press the EN TER key 6 Use the NUMERIC keys to enter the new code 7 Press the ENTER key to confirm 8 CONFIRM i...

Page 86: ... type e g User you wish to alter then press the ENTER key 4 Use the LEFT or RIGHT key to select the Code e g User 11 you wish to alter 5 Press the DEL key You are asked whether you want to delete the code 6 Select YES using the LEFT or RIGHT key then press the EN TER key 7 Press the ENTER key to confirm the deletion Note The Master Code cannot be deleted Upon deletion of a Manager Code the corresp...

Page 87: ...ired display language Press the ENTER key to confirm 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 5 2 Enabling disabling Remote Disable Submenu RMT DIS Opening of the closed lock can be disabled by an external signal This function can e g be employed when additional identification e g badge biometrics is desired or to prevent opening dur...

Page 88: ...he general beeper volume Authorization Master Code 1 Select submenu VOLUME 2 Press the ENTER key The current volume is displayed 3 Use the LEFT or RIGHT key to set the desired volume 000 for off 001 for low and 002 for high volume 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 5 4 Enabling disabling Open Beeper Submenu OPEN beep This setti...

Page 89: ...nds Authorization Master Code 1 Select submenu CNF WIN beep 2 Press the ENTER key The information if the beeper is switched on or off is displayed 3 Select either ON or OFF by toggling with the LEFT or RIGHT key then press the ENTER key to confirm 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 5 6 Enabling disabling Delay Notify Beeper Sub...

Page 90: ... beeper is switched on or off is displayed 3 Select either ON or OFF by toggling with the LEFT or RIGHT key then press the ENTER key to confirm 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 5 8 Enabling disabling Wait time display Submenu WAIT info This setting defines if the waiting time period is displayed Authorization Master Code 1 Se...

Page 91: ...anguage 4 Upon defining the last language select in the upcoming dialogue YES using the LEFT or RIGHT key then press the ENTER key to con firm 6 4 5 10 Activating Deactivating Code Denial Submenu CDE DEN bank A higher level code can deny access for lower levelled codes until possible re permission As an example Off Duty Shifts can be locked out and reassigned again once they start their shift An e...

Page 92: ...indicated with in the display 6 4 5 11 Activating Deactivating Duress Code function Submenu DURESS bank If the lock is connected to an external alarm system a silent duress alarm not noticeable for the aggressor can be triggered by entering a Duress Code Duress Code on page 46 Duress Codes are recognized if this function has been activated Entering the Duress Code for opening the lock also starts ...

Page 93: ...Mode 4 Press the ENTER key to confirm the setting in the upcoming save dialogue Note Depending on the Dual Mode settings Two Codes of same group Two Codes of different groups or any two codes different code combinations Manager and Master User and User Manager and User etc can open the lock Master Code if set to Master can open Lock and Courier Code can open the lock without any second code If Ope...

Page 94: ...de is programmed in Dual Mode Master Code can open though 6 4 5 13 Enabling disabling One Shot Codes Submenu ONE SC4 bank This setting defines if the codes of the group 4 are used as one shot codes If defined as such the codes defined can be used only once After the us age the code will not be valid for opening another time Authorization Master Code 1 Select submenu ONE SC4 bank 2 Press the ENTER ...

Page 95: ...firm 4 In the upcoming dialogue select YES using the LEFT or RIGHT key then press the ENTER key to confirm 6 4 5 15 Enabling disabling Non Return Time Delay Submenu NRTD cit Ex factory the Non Return Time Delay does apply for OTM codes as well If the Non Return Time Delay shall not apply for OTM codes set this setting to OFF Example The lock is used in bank mode with NRTD set The OTM codes are use...

Page 96: ...lock is valid for OTM as well Enabling disabling Time Lock for OTM Submenu TL LOCK cit on page 96 Show the current time so that the user can compare to the time lock setting Authorization Master Code 1 Select submenu TIME cit 2 Press the ENTER key It is displayed if the current time is displayed on or not displayed off 3 Select either ON or OFF by toggling with the LEFT or RIGHT key then press the...

Page 97: ...NE batteries or 1 5 Volt Lithium batteries type AM3 AA with a service life of approximately 1 to 2 years about double with Lithium batteries Batteries must be replaced once the battery low symbol appears in the display at least if the text prompts CHANGE BATT The lock remains fully operational until the battery voltage drops below the value required for correct operation Proceed as follows 1 Undo ...

Page 98: ...ent and fix it with the screw Wait until the error message BAT CMP OPEN reappears again 6 Confirm the message by entering the Master Code or one of the Manager Codes The lock opens and closes again after the set opening time The Lock is in normal operating mode If no reaction on Master Code or Manager Code close lock with door open If still no reaction wait 2 minutes and enter Master Code or Manag...

Page 99: ...ESSOR CITLOCK Axessor CIT input unit model number 3310300311 AXESSOR CITIU Battery compartment for Axessor input unit 52x BAT S Spare Administrator dongle for Software AS284 W AS284 AW Spare Operator dongle for Software AS284 W AS284 OW Spare Installer dongle for Software AS280 W AS284 INSW Axessor installation kit 52x INST S Installation kit for Axessor CIT eBox 528BX INST Connector for Axessor C...

Page 100: ...41 49 ID is not 90 REFUSED CODE MASTER MANAGER USER COURIER Code modification Code entered did not match the code entered first REFUSED 02 Unknown command Desired function not available Installed components not compatible Call vendor for technical sup port REFUSED 04 PROG IMM TL No Weekly Locking Period programmed after confirmation of an entry in Programming Mode Lock is closed programming possib...

Page 101: ... minimum time period is calculated by adding the confirmation window plus one minute to the bigger value of the two delay times time delay or duress time delay REFUSED 32 PROG WEEK Memory full max 35 Weekly Locking Periods PROG HOLIDAY Memory full max 22 Holiday Locking Periods REFUSED 64 Unexpected data error Try again Call vendor for technical support if error keeps re appearing REFUSED 128 Lock...

Page 102: ...or notice Page 103 Axessor CIT Display Menu Submenu Cause HDW FLT Hardware fault Proceed as with MOT FLT If multiple causes lead to multiple error messages REFUSED xx the error numbers will be added Examples REFUSED 12 REFUSED 04 REFUSED 08 REFUSED 50 REFUSED 02 REFUSED 16 REFUSED 32 ...

Page 103: ... User Codes 8 digits each subordinated in 4 groups of 9 each to the respective Manager Code bearer e g Cashier Sales Assistant Note User Codes 48 and 49 can be set to disable enable lock opening with AS284 USBW or AS284 NETW Programming Software 1 Courier Code 8 digits opening permission without opening delays bearer e g auditor CIT Cash In Transit service provider etc Note opens alone in Dual Mod...

Page 104: ...r Manager 1 and User 11 19 Time Delay 2 valid for Manager 2 and User 21 29 Time Delay 3 valid for Manager 3 and User 31 39 Time Delay 4 valid for Manager 4 and User 41 49 1 Time Delay for one time code mode Duress Time Delays 4 Duress Time Delays for bank mode 99 min Duress Time Delay 1 valid for Master Manager 1 and User 11 19 Duress Time Delay 2 valid for Manager 2 and User 21 29 Duress Time Del...

Page 105: ... from 6 to 60 seconds for bank mode and from 6 to 120 sec onds for one time code mode with AS284 USBW or AS284 NETW Programming Software Manually Upon pressing DEL key After closing of bolt work Event memory Approx 10 000 event entries protected against manipulation and power failure Shelve Function Master Code can delete respectively reset all codes functions and settings back to factory default ...

Page 106: ...arm factory setting Output 2 Bolt or motor open factory setting With the Programming Software AS284 USBW or AS284 NETW the outputs can be programmed for different applications For this e g the following events are available Lock open Door open Active time delay Active penalty time Duress code entry Battery compartment open and more Inputs Input 1 signal triggered 12VDC 20mA not programmed factory ...

Page 107: ...istance force 1000 N in all directions Moving force Max 5 N both directions Environmental condi tions Operation 0 50 C storage 10 60 C Service life 50 000 cycles PCB designation A21 P 01 05_L Input Unit Dimensions 128 193 x 90 x 40 mm Weight 660 g including connection cable and batteries Environmental conditions Operation 0 50 C storage 10 60 C system of protection IP53 PCB designation A08 P 03 04...

Page 108: ...approval only valid if marked on lock Underwriter Labora tories UL High security electronic lock type 1 approval only valid if marked on lock Note The audit features the software features features associated with peripheral devices and systems optional interconnect devices and their associated features features involving the use of user keys the duress feature monitoring features remote features o...

Page 109: ...ax 4 groups of 9 not activated User Code settings cannot activate IMM TL Users 48 49 to disable enable opening not activated Courier Code not activated Courier Code settings can open Duress Code entry not activated Dual Mode not activated Dual Mode setting any two codes Dual Manager for Programming Mode not activated Manager Cross Access User Codes not activated Number of wrong codes until penalty...

Page 110: ... activated Input 1 b connections 5 and 6 Remote Disa bling Input 2 c connections 7 and 8 not programmed door contact skip Time Delay Time Lock interruption ext Input Event A F Output 1 d connections 3 and 4 Duress alarm Output 2 d connections 1 and 2 bolt or motor open Remote Disabling not activated Buzzer volume high Beep every 30 sec while lock open on Beep every 60 sec while Duress Time Delay c...

Page 111: ...M_Axessor_CIT_V024_20170518_EN pdf Operating Manual Page 112 Subject to change without prior notice Axessor CIT Template Input Unit 40 41 3 55 10 4 x M4 1 3 2 6 10 6 5 4 193 90 mm inch 50 100 1 2 3 4 0 0 ...

Page 112: ...ut prior notice Page 113 Axessor CIT Template Lock 1 2 3 4 5 6 7 8 41 3 66 7 3 x Ø5 7 9 max 1000N max 1000N max 5N max 1000N 11 5 15 2 x M4 13 2 5 25 2 7 8 Type Part No Serial No Version Certs AXESSOR CIT XXXXXXXXXX XXXXX XXXXXX XXX xxxxx xx 2017 VdS mm inch 50 100 1 2 3 4 0 0 ...

Page 113: ...OM_Axessor_CIT_V024_20170518_EN pdf Operating Manual Page 114 Subject to change without prior notice Axessor CIT Template eBox 93 5 106 5 27 27 mm inch 50 100 1 2 3 4 0 0 ...

Page 114: ...his documentation may not be reproduced or distributed in any way neither in digital nor in pho tographic form without prior written permission of dormakaba AG by dormakaba AG CH 8620 Wetzikon Document OM_Axessor_CIT_V024_20170518_EN pdf Edition May 2017 ...

Reviews: