OM_Axessor_CIT_V024_20170518_EN.pdf Operating
Manual
Page 102
Subject to change without prior notice
Axessor CIT
Display
Menu
Submenu
Cause
REFUSED
16
PROG
WEEK
Minimum interval (pause) of 1
day until start of next Weekly
Locking Period ignored. Also
observe delay / confirm win-
dow limits.
PROG
HOLIDAY
Minimum interval (pause) of 1
day until start of next Weekly
Locking Period ignored. Also
observe delay / confirm win-
dow limits.
PROG
DELAY
Observe delay / confirm
window limits in relation to
Weekly and Holiday Locking
Periods.
The minimum time period
is calculated by adding the
confirmation window plus one
minute to the bigger value
of the two delay times (time
delay or duress time delay).
REFUSED
32
PROG
WEEK
Memory full (max. 35 Weekly
Locking Periods)
PROG
HOLIDAY
Memory full (max. 22 Holiday
Locking Periods)
REFUSED
64
Unexpected data error. Try
again.
Call vendor for technical
support if error keeps re-
appearing.
REFUSED
128
Lock is no longer in program-
ming mode (only menu naviga-
tion but no data sent to lock
for
>5 minutes).
MOT FLT
Motion Fault during bolt
movement.
• Reboot unit by removing
batteries for one hour and
inserting new batteries.
• Check if bolt movement is
smooth or if bolt is mechani-
cally blocked
• Call vendor for tech support
(replace lock)
Summary of Contents for Axessor CIT