6.4.2.5 Configuring Time Related Function - Submenu TR-FNC1..3
This function permits defining of up to 3 time-related functions, during
which the lock changes the behaviour. Possible settings are Open Time De-
lay, toggle Dual Mode and Code Disabling. Optional it can be defined for
which days it applies. Three Time Related Functions can be programmed:
• Time Related Functions 1: valid for Master, Manager 1 and Users 11 ... 19
• Time Related Functions 2: valid for Manager 2 and Users 21 ... 29
• Time Related Functions 3: valid for Manager 3 and Users 31 ... 39
Authorization: Master
Code
6.4.2.5.1 Adding a
Time Related Function
1. Select submenu „
TR-FNC1
“, “
TR-FNC2
” or “
TR-FNC3
”.
2. Press
the
<ENTER>
key. If any Time Related Functions are already
defined, the count is displayed.
3. Press
the
<ENTER>
key to enter a new Time Related Function.
Note!
If the maximum of 3 Time Related Functions are already defi ned upon pressing
the „ENTER“ key the display does not change / react.
4. Use
the
<LEFT>
or
<RIGHT>
key to set the hour of the
starting point of
the Time Related Function
(indicated by the „
lock closed
” symbol) and
the
<ENTER>
key for confirmation. Repeat this to set the minutes.
5. Use
the
<LEFT>
or
<RIGHT>
key to set the hour of
end point of the
Time Related Function
(indicated by the „
lock open
” symbol) and the
<ENTER>
key for confirmation. Repeat this to set the minutes.