Electric Rim Strikes Installation Instructions 

The ES1934 / ES1912 series electric rim strikes are 

surface mounted and designed to accommodate rim

exit devices with a pullman latch.  No cutting on the

frame is required for installation. These strikes are 

field selectable for fail-safe or fail-secure mode and

operate on dual voltage 12 / 24 VDC.
Available with optional latch monitor.

Specifications 

Model 

ES1934 

I

ES1912 

ES1934-M 

ES1912-M 

Operating Voltage 

12124 voe 

Current Draw 

540mA 

12VDC, 270mA / 24VDC 

Operating Temperature  14

°

F to 120

°

F (-10

°

C-+49

°

C) 

Humidity 

0-85% non-condensing

Static  Strength 

1500 lbs (680Kg) 

Dynamic Strength 

70 ft-lbs 

Endurance Rating 

250,000 cydes (UL tested) 

1,000,000 cydes (Factory tested) 

Lock Mode 

Field selectable fail-safe 

or fail-secure 

Destructive Attack:  Level  I 

Performance Level 

Line  Security:  Level  I 

Standby Power:  Level  I 

Endurance:  Level  IV 

Finish 

Brushed Stainless Steel (US32D) 

or Black (US1) 

Frame Application 

Metal or Wood 

Latch Throw 

3/4" 

I

1/2" 

(Housing Thickness) 

UL Requirements 

• For indoor use only 

• The ES1934 / ES1912 Series are intended to be used with

UL Listed Exit Hardware. 

• The ES1934 / ES1912 Series electric strikes are access control unit 

accessories, intended to be controlled by an access control system.

The access control systems purpose is to provide a means for

controlling the locking and unlocking of external and internal doors 

of a premise.

• The ES1934 Series shall not be installed in the fail secure mode

unless permited by the local authority having jusrisdiction and shall 

not interfere with the operation of panic hardware. 

• The Fire Rated ES 1934 Series electric strike is to be used only with

UL Listed Rim Type Fire Exit Hardware, Von Duprin LLC,  Model 99-F. 

• Remove the Listed Fire Rated Hardware label if the ES1934 Series 

Electric Strike will be used in the fail safe operation. Using the above 

mentioned strike in fails safe operation negates the fire rating. 

• The ES1934 Series Electric Strike is Fire Rated in Fail Secure

operation only. 

CAL-ROYAL 

P  R  O  D  U  C  T  S,  I  N  C.  U.S. A. 

Surface Installation 

'<, / 

...---1 

39

1

x; 

{1011mm) 

Measure 39 13/16" 

(1011 mm) up from 

finished floor and mark 

strike centerline on 

door. Transfer 

centerline to frame. 

Align strike on 

centerline and mark 

two slotted holes. 

Drill holes and install 

strike to frame. 

Align template on 

centerline and 

against strike. 

Surface Installation (For Exit Device Already Installed) 

Model ES1912 is used as example below. 

Inside of 

Strike Keeper 

Latch  Position Line  � 

a. Measure the exit device latch

position on the door. 

a. Close the door and mark latch

position on the frame. 

b. The latch position line will

correspond with the inside of strike 

keeper as shown. 

a.  Position the strike on the frame

according to the marked latch

position. 

b. Use the strike as a template; mark

and drill cable access hole and two 

mounting holes. 

c. Loosely mount the strike with

Phillips flat head screws. 

a. Check latchbolt interaction and

adjust the strike horizontally until

the door latches properly. 

b. Tighten the two mounting screws 

and mark remaining screw holes. 

a.  Remove the strike and drill holes. 

b. Connect the wires. 

c.  Insert the blind nuts into the holes 

and re-install the strike. 

d. Add spacers to adjust the gap 

between strike and exit device if 

necessary. 

e.  Permanently secure the strike with

the hex socket cap screws into the

blind nuts.

DWG # ELG801