CA L•R OYAL
ES1934 / ES1912 Series
PRODUCTS, INC .
Electric Rim Strikes Installation Instructions
The ES1934 / ES1912 series electric rim strikes are
surface mounted and designed to accommodate rim
exit devices with a pullman latch. No cutting on the
frame is required for installation. These strikes are
field selectable for fail-safe or fail-secure mode and
operate on dual voltage 12 / 24 VDC.
Available with optional latch monitor.
Specifications
Model
ES1934
I
ES1912
ES1934-M
ES1912-M
Operating Voltage
12124 voe
Current Draw
540mA
I
12VDC, 270mA / 24VDC
Operating Temperature 14
°
F to 120
°
F (-10
°
C-+49
°
C)
Humidity
0-85% non-condensing
Static Strength
1500 lbs (680Kg)
Dynamic Strength
70 ft-lbs
Endurance Rating
250,000 cydes (UL tested)
1,000,000 cydes (Factory tested)
Lock Mode
Field selectable fail-safe
or fail-secure
Destructive Attack: Level I
Performance Level
Line Security: Level I
Standby Power: Level I
Endurance: Level IV
Finish
Brushed Stainless Steel (US32D)
or Black (US1)
Frame Application
Metal or Wood
Latch Throw
3/4"
I
1/2"
(Housing Thickness)
UL Requirements
• For indoor use only
• The ES1934 / ES1912 Series are intended to be used with
UL Listed Exit Hardware.
• The ES1934 / ES1912 Series electric strikes are access control unit
accessories, intended to be controlled by an access control system.
The access control systems purpose is to provide a means for
controlling the locking and unlocking of external and internal doors
of a premise.
• The ES1934 Series shall not be installed in the fail secure mode
unless permited by the local authority having jusrisdiction and shall
not interfere with the operation of panic hardware.
• The Fire Rated ES 1934 Series electric strike is to be used only with
UL Listed Rim Type Fire Exit Hardware, Von Duprin LLC, Model 99-F.
• Remove the Listed Fire Rated Hardware label if the ES1934 Series
Electric Strike will be used in the fail safe operation. Using the above
mentioned strike in fails safe operation negates the fire rating.
• The ES1934 Series Electric Strike is Fire Rated in Fail Secure
operation only.
CAL-ROYAL
P R O D U C T S, I N C. U.S. A.
Surface Installation
'<, /
...---1
39
1
x;
{1011mm)
Measure 39 13/16"
(1011 mm) up from
finished floor and mark
strike centerline on
door. Transfer
centerline to frame.
Align strike on
centerline and mark
two slotted holes.
Drill holes and install
strike to frame.
Align template on
centerline and
against strike.
Surface Installation (For Exit Device Already Installed)
Model ES1912 is used as example below.
Inside of
Strike Keeper
Latch Position Line �
a. Measure the exit device latch
position on the door.
a. Close the door and mark latch
position on the frame.
b. The latch position line will
correspond with the inside of strike
keeper as shown.
a. Position the strike on the frame
according to the marked latch
position.
b. Use the strike as a template; mark
and drill cable access hole and two
mounting holes.
c. Loosely mount the strike with
Phillips flat head screws.
a. Check latchbolt interaction and
adjust the strike horizontally until
the door latches properly.
b. Tighten the two mounting screws
and mark remaining screw holes.
a. Remove the strike and drill holes.
b. Connect the wires.
c. Insert the blind nuts into the holes
and re-install the strike.
d. Add spacers to adjust the gap
between strike and exit device if
necessary.
e. Permanently secure the strike with
the hex socket cap screws into the
blind nuts.
DWG # ELG801
5
, P1/
2
, 20220407