6
EN
6. Assembly
- 41 -
951-171-010
Version 06
Set the pulse mode Fig. 22
1
ON
2 3 4 5 6 7 8
1
0
9
Cover plate Fig. 21
2.1
2
Set definite pulse value
DIP 1
DIP 2
DIP 3
DIP 4 Pulses
0
0
0
1
1
0
0
1
0
2
0
0
1
1
3
0
1
0
0
4
0
1
0
1
5
0
1
1
0
6
0
1
1
1
8
1
0
0
0
10
1
0
0
1
20
1
0
1
0
30
1
0
1
1
40
1
1
0
0
50
1
1
0
1
60
1
1
1
0
80
1
1
1
1
100
6.14 Pulse mode
To set the mode proceed as follows:
• Unscrew the screws (2.1) and keep them
for future use.
• Remove the cover plate (2).
ATTENTION
Damage to the pcb is possible by slipping
off with an inappropriate adjusting tool.
Ensure that the adjusting tool is firmly
seated in the respective DIP switch.
The position of DIP switch 5 is
not relevant for this operating
mode.
6.15 To set the pulse mode
• Bring DIP switch 7 into position 1.
• Bring DIP switch 8 into position 1.
6.16 Adjusting the output volume
• Bring DIP switch 6 into the desired
position.
• Position 1 = approx. 1.0 ccm/ stroke
Position 0 = approx. 0.5 ccm/ stroke
6.17 To set the pulses
• Bring DIP switches 1-4 into the desired
positions.
• Reinstall the cover plate (2).