EN
6. Assembly
- 40 -
951-171-010
Version 06
Set the machine contact mode Fig. 20
1
ON
2 3 4 5 6 7 8
1
0
9
Cover plate Fig. 19
2.1
2
Presettings
seconds
DIP 5
0
hours
DIP 5
1
Set definite time value
DIP 1 DIP 2 DIP 3 DIP 4 seconds hours
0
0
0
1
60
1
0
0
1
0
70
2
0
0
1
1
80
3
0
1
0
0
90
4
0
1
0
1
100
5
0
1
1
0
110
6
0
1
1
1
130
7
1
0
0
0
150
8
1
0
0
1
190
9
1
0
1
0
250
10
1
0
1
1
480
11
1
1
0
0
750
12
1
1
0
1
1000
13
1
1
1
0
1250
14
1
1
1
1
1600
15
• Unscrew the screws (2.1) and keep them
for future use.
• Remove the cover plate (2).
ATTENTION
Damage to the pcb is possible by slipping
off with an inappropriate adjusting tool.
Ensure that the adjusting tool is firmly
seated in the respective DIP switch.
6.11 To set the machine contact mode
• Bring DIP switch 7 into position 1.
• Bring DIP switch 8 into position 0.
6.12 Adjusting the output volume
• Bring DIP switch 6 into the desired posi-
tion.
Position 1 = approx. 1.0 ccm/ stroke
Position 0 = approx. 0.5 ccm/ stroke
6.13 To set the pause time
Presettings
• Bring DIP switch 5 into position 0 (sec-
onds) or 1 (hours).
Setting of definite value
• Bring DIP switches 1-4 into the desired
positions.