Fault table
Fault
Possible cause
Remedy
Air pockets in the lubricant or
lubrication system
Loosen inlet fitting. Visual check for bubbles in the lubricant
Loosen outlet fitting. Visual check for bubbles in the
lubricant
If necessary, vent the lubrication system. To do so, observe
the instructions of the upstream pump.
Vent lubrication system. To do so, trigger an additional lubri-
cation several times, if necessary.
Defective pressure relief valve
Overpressure in the centralized
lubrication system
Lubricant leaking from the pressure reducing valve
Replace pressure reducing valve.
Determine and remedy cause of overpressure
Lubricant volume deviates
from projected values
Pause (DIP switch 1-4) set wrongly
Output volume (DIP switch 6) set wrongly
Check and, if necessary, correct pause settings (time or
pulses)
Check and, if necessary, correct output volume setting
If the fault cannot be determined and remedied, please contact our Customer Service.