EN
4. Technical data
- 26 -
951-171-010
Version 06
4.3 Functions of the DIP switches
DIP switches 1-4
Serve to set the definite value for the pause.
(Details see chapters 4.4, 4.5, 4.6)
DIP switch 5
Serves to set the pause time to seconds or
hours
0 = seconds
1 = hours
DIP switch 6
Serves to adjust the metering quantity
1 = 1.0 ccm/ stroke (full stroke)
0 = 0.5 ccm/ stroke (full stroke)
DIP switches 7-8
Serve to set the different operating modes.
DIP switch 7
0 = Setting to the ON/OFF mode
1 = Pre-selection of machine contact mode
or pulse mode
DIP switch 8
0 = machine contact mode
1 = pulse mode
DIP switch 9
Serves to set the external pressure switch
0 = OFF
1 = ON
Setting of pause time DIP 1-4 Fig. 5
Setting of pause time DIP 5 Fig. 6
Setting of pause time DIP 7-8 Fig. 8
1
ON
2 3 4 5 6 7 8
1
0
9
1
ON
2 3 4 5 6 7 8
1
0
9
1
ON
2 3 4 5 6 7 8
1
0
9
Setting of pause time DIP 6 Fig. 7
1
ON
2 3 4 5 6 7 8
1
0
9
Pressure switch ON/
OFF DIP 9 Fig. 9
1
ON
2
4 5 6 7 8
1
0
3
9