4. Technical data
- 31 -
951-171-010
Version 06
4.13 Machine contact mode
Cycle time
approx. 60 seconds
Lubrication time
approx. 15 seconds
Lock-out time
45 seconds
Duty cycle
>
60 seconds
Additional lubrication cycle
possible within lock-out time
YES
Adjustable pause
YES
minutes/hours
Residual pause
after switching off
Time counter
(persistent)
Setting the mode via DIP switches
DIP switch 7
Position 1
DIP switch 8
Position 0
Variable DIP switches for this mode
DIP switches 1-4
Position 0 or 1
DIP switches 5, 6
Position 0 or 1
1
ON
2 3 4 5 6 7 8
1
0
9
Application example:
The EDL1 shall carry out a lubrication cycle
according to the pause time value (example
= 4 hours) set via DIP switches 1-5.
Setting the machine contact mode, see
chapter 6.10.
Machine contact mode Fig. 11
1
Power 24 V DC
2
Mass (-)
3 PE
4
Power supply of 24 V DC
5
Mass of sensor (–)
6
Signal of sensor
8/9
Fault signal
(potential-free)
10/11 Feedback (potential-free)
(lubrication cycle successfully completed)
If terminals 4 and 6 are bridged,
the EDL1 can be operated also
autonomously without machine
contact.