3. Overview, functional description
6.4 "Additional lubrication/ Reset" key
Additional lubrication
An additional lubrication cycle is triggered by
pressing the key < 5 seconds.
Reset
An reset is triggered by pressing the key > 5
seconds.
6.5 Red LED (Fault signal terminal 8/9)
Is lit when:
○
a malfunction is present.
6.6 Yellow LED (Feedback terminal 10/11)
Is lit when:
○
the last lubrication cycle has been completed
successfully and EDL1 is ready for operation.
6.7 Protective conductor terminal
○
Serves to connect the protective conductor
For details regarding the operating states and
fault messages, see chapter 10.1
Overview Fig. 4
6.4
6.5
6.6
6.7