Page 75
EN
Securing parameters during network failure
Nonvolatile memory EEPROM
One input for external acknowledgment of
the error message
1)
(RESET).
One input for switching over to start up
operation
1)
Monitoring per signal input
Full-load operation:
2 x lower limit
(warning, underlubrication fault)
1 x upper limit
(overlubrication warning)
Start up operation:
2 x lower limit
(warning, underlubrication fault)
Signal outputs
Type of contact 2 changeover switches (isolated)
max. switching voltage
250 V AC
max. switched current
2 A
max. switching capacity 250 VA
Measuring principle:
Measuring range
10...2400 pulses/min.
Mean value from individual periods
The following applies to every measuring
point:
max. period duration
100 s.
corresponding to roughly
0.6 pulses/min
max. measuring time:
100 s +
1 period max.
Input freq.
[pulses/min.]
Messuring time
[ s ]
3600
1
1200
3
360
5
90
10
14
30
2.25
80
0
100
Plausibility check:
Every error must occur in at least two
measurements in a row for an error message
to be issued.
Measuring resolution (meas.exactness)
up to
500
pulse/min:
≤ 1.0 %
up to
750
pulse/min:
≤ 1.5 %
up to
1000
pulse/min:
≤ 1.0 %
Caution!
Suficient spark extinction has to be
provided for DC loads.
6. Description of components
Summary of Contents for IPM 12
Page 47: ...Seite 47 DE...
Page 51: ...Seite 51 DE 11 4 COMO Zentralschmiersystem berwachung 11 Anschlussbeispiele Men struktur...
Page 53: ...Seite 53 DE...
Page 101: ...Page 101 EN...
Page 105: ...Page 105 EN 11 4 Overview COMO Lube System Monitoring 11 Connection example menu structure...
Page 107: ...Page 107 EN...