basic settings on the PGA 3, Table 2 from 3
Step
Key
Function
7
Enter uptime between IMP 12 and PGA 3 (data transfer)
Press
function key F3
The cursor is located at the menu’s uptime IPM input position, the uptime input position of the IPM 12
Use the
numeric keypad
to enter the uptime [sec]
Press the
ENTER
key
8
Enter uptime between the Ethernet server and PGA 3 (data transfer)
Press
function key F4
The cursor is located at the menu’s uptime Ethernet input, Ethernet server uptime input, input in seconds).
Use the
numeric keypad
to enter the uptime [sec]
Press the
ENTER
key
9
Select port, local and remote menu
Press
next step function key
The port, local and remote menu is jumped to.
10
Enter port address
The port address is a transfer address in the ITP protocol. It controls the exchange of data between the PGA 3 and OPC server.
If there is no Ethernet interface (no OPC server) there is no need to enter an address.
Press
function key F2
Use the
numeric keypad
to enter the port address
Press the
ENTER
key
8. Startup
3
4
2