Maintenance
8.1 Maintenance plan
Maintenance tasks that are required for optimal and trouble-free
operation are described in the sections below.
If increased wear is detected during regular inspections, shorten
the required maintenance intervals according to the actual indica-
tions of wear.
!
Note!
If the telescopic pillar is used outside the environmental
conditions specified earlier in this manual, check the device once
a month for any changes, such as oxidation or sedimentation.
Interval
Maintenance work
To be carried out by
Daily
Clean dust and dirt from the pillar (
†
Chapter
8.2.1 Cleaning
,
page 42
).
Operator
Check pillar for visible damage (
†
Chapter
8.2.4 Visual check of
external condition
,
page 44
).
Qualified personnel
Check pillar for unusal noise or change in performance
Qualified personnel
Monthly
Check the function of operating features and safety equipment.
Qualified personnel
Check the attachments of the device to the upper and lower
attachment plates.
Qualified personnel
Every 6 months
Check the function of the emergency cut-off switch, if present.
Qualified electrician
Check that all plugs are properly inserted.
Operator
As determined by the
processor
Conduct visual inspection of the routing of the motor and controller
cables within the application. Cable routing elements should not be loose
or broken.
Qualified electrician