6.3 Installation
•
To be performed by qualified personnel
6.3.1 Installation overview
The telescopic pillar CPMT can be mounted to the application via the
SKF mounting plates available as accessory, or directly to the appli-
cation. Mounting has to be done via the attachment bores on the
outer and inner tube, which are accessible through the top and base
plates (
†
fig. 1
,
page 23
).
Screw
8 × M10
Screw-in depth
25 to 35 mm in the pillar
Strength class
10,9
Tightening torque
40 Nm
The telescopic pillar CPMT can be mounted with the outer tube or
the inner tube at the bottom. If the inner tube is fixed and the outer
tube is able to move in the application, ensure that there is no pos-
sibility of strain or pinching of the power cable.
Any subsequent fastening bores in the aluminium tubes may be
made only by SKF.
Care must be taken not to damage or scratch the sides of the
tubes, as this can damage the guiding system and lead to product
malfunctions.
Risk of injury and device damage due to manipulation of the
screws on the device
Manipulation or loosening of the screws on the device or the
optional devices may lead to injury and device damage during
the operation.
Therefore:
•
Never loosen screws on the device or the options, except the
transportation screws installed in the mounting bores.
W A R N I N G
The outer and inner tube base plates are not designed to
support the rated load of the pillar without additional support
provided by mounting plates. If a custom mounting plate is
used, ensure that it is dimensioned to provide sufficient support
of the base plates.
C A U T I O N