For the 2-Hall encoder impulse transmitter, the third party control
unit must fulfill the following additional requirements:
•
Feed the hall sensors with a current of 4,5–26,5 V DC and a
current limit of no more than 200 mA.
•
Load the hall sensor outlets with a maximum of 20 mA.
•
Connect the hall sensor outlets to the supply with pull-up resistors
so that the signal of the open collector outlets can be analyzed.
4.4 Connections
Electrical connection
The telescopic pillar is connected to the control unit via the DIN-8
plug or the flying leads cable.
Connected load is 24 V–30 V DC and up to 12 A according to the
technical data (
†
Appendix
,
page 52
).
Important:
Ensure that cables cannot get pinched or damaged.
Check that the mains voltage corresponds to the nominal values on
the type plate.
Pin allocation and lead color code are given in the technical specifi-
cation in the
appendix
.
Mechanical connections
Outer tube section base plate
Inner tube section base plate
Mounting plate
(accessory)
101
101
146
146
M10
15
50
M10
35
Fig. 6
Fig. 5
23