Installation and first operation
6.3.2 Installation steps
1
Remove the transportation screws from the mounting bores at
the outer and inner tube base plates.
2
Fasten the mounting plates, or the attachment points in the appli-
cation, to the mounting bores at the outer and inner tube base
plates.
IMPORTANT:
Screw in to a minimum of 25 mm and torque the
screws with 40 Nm.
3
Check that all screws are sufficiently secured against
self-loosening.
4
Check that all interfaces and connections have been mounted
and/or connected correctly.
5
Ensure that the motor cable cannot be crushed, jammed or pulled
during operation, due to tension or pressure.
6
You are now ready to connect and operate the telescopic pillar
using the corresponding control unit and operating device.
Before connecting the telescopic pillar CPMT to a control unit,
ensure that:
•
the telescopic pillar CPMT is attached to the metal plates of the
application on
both sides
•
all attachment points are securely screwed to the application
•
the elements are
fully
aligned and seated at the top and bottom
•
the areas for force distribution are supported
•
the acting force does not impact the guide tubes with inadmissibly
high values, as side-impacting forces that are too high can destroy
the telescopic pillar CPMT
•
the telescopic pillar is not obstructed in any way in the entire lift-
ing area
•
the cables are not pinched, or caught or subject to tension, bend-
ing, or pull stress.
Risk of injury and device damage due to insufficient
fastening
Use fastening bolts only, and secure them adequately. Do not
use screws to install. Never loosen or otherwise manipulate
screws on the device or options.
W A R N I N G
!
Note!
Fastening screws are not supplied. The bore dimensions
can be found in
Plans and diagrams
,
page 53
.
32
www.lmotion.ru
Тел
.: (495)-921-34-60