MultiXplo / MultiTox
Page 23 / 60
NOSP15759-Rev 10
4.3.3.
Installation recommendation
There are three different type of power supply:
-
3-wires connection (source) :
The output current is not isolated from power supply, provided from detector (standard
connection).
-
3-wires connection (sink) :
The output current is not isolated from power supply, consumed by the detector
-
4-wires connection :
The output current is isolated from power supply
NB :The power potentials are isolated fromthe electric ground of the housing.
Total loop resistance:
Whatever the power supply type (3 wires source ou sink, 4 wires), the total loop resistance
(re cable) should not exceed the following value:
mA
22
V
8
tage
supply vol
Power
maxi
R
−
=
The total loop resistance should not exceed 700
Ω
with a voltage of 24Vdc.
Terminal blocks
Point
JP11
Description
1
V-
0 V
2
V+
+24VDC power supply
3
V+
+24VDC power supply loop (connected to point 2)
4
V-
0 V, Connected to point 1
5
L+
20mA Current loop: entry
6
L-
20mA Current loop: output