background image

USER MANUAL

Summary of Contents for Golden King

Page 1: ...USER MANUAL ...

Page 2: ...S that can clean the received signal no matter what the reason of distortion is What we get is always a clean sinusoid that is easy to process Equipment Safety Especially during transportation do not forget that this is an electronic device and do not expose it to harsh impacts Waterproofness The system box of the equipment is not completely waterproof It should not be exposed to rain or soaked in...

Page 3: ... to the instructions written in the user s manual prepared by Nokta Engineering Do not expose the battery to heat Important Note If the lithium polymer battery used on the system is exposed to high heat or direct sunlight it may get damaged Never leave it inside a car in hot weather Short circuiting of the lithium polymer battery may also cause it to get damaged Installation Your equipment is elec...

Page 4: ...egative results due to wrong usage of the device Language Selection The Golden King Deep Processor Radar can operate in 10 different languages Turkish English Greek Persian Bulgarian French Spanish German Russian and Arabic Operating Manual The Golden King Deep Processor Radar contains an operating manual The user can access the warnings about the equipment correct usage and other useful informati...

Page 5: ... methane gas or not that may adversely affect the human health Camera Recorder The Golden King Deep Processor Radar is equipped with a special camera recorder as an attachable accessory which operates at a very high display quality even 30 meters under water has night vision thus allowing use both on land and under water Saving With the Golden King Deep Processor Radar system you can save the resu...

Page 6: ... Headphones All these parts can be obtained from the dealers of Nokta Engineering Please do not use any external or any other branded item Unpacking Equipment Clamping apparatus to adjust the monitor angle Multi functional keypad Speakers Search coils socket input Gas sensor socket input 7 TFT monitor Headphones socket input Camera recorder input Battery compaction apparattus Battery Battery compa...

Page 7: ...ton Warning Lights When the battery is inserted in the device if the ON OFF button is pressed all 3 LEDs will blink once in order When the battery is ON but not inserted properly in the device the yellow LED will blink constantly Yellow LED When the battery is empty the yellow LED will blink fast and the device will shut down When the battery is ON but not inserted properly in the device the yello...

Page 8: ...em first you need to press the STANDBY button on the keypad Then you need to press the OFF button on the battery After the battery is taken out of the bag it is installed in its place on the system box by the connection screws The extension bar to which the armlet and the joystick are connected is removed from the bag The search coil is attached to the bobbin connection component on the extension ...

Page 9: ...e in when you press the info key you will view detailed information about that section or menu Also in this section the user will be informed about the following steps Ground Balance Key This key is used to access the ground balance menu You can select either the automatic or the manual option from the ground balance menu when needed Brightness Setting Once the brightness setting key is pressed it...

Page 10: ...und balance screen Confirm Button The confirm button on the joystick is used to confirm the operations the system warns the user for Numeric Keys It is the multi functional section of the keypad Especially at the time of recording it lets you enter the Date Region Name and the Time Press the key until the character you desire appears on the screen You can delete any letter or number by using the D...

Page 11: ...ave selected by pressing the OK key This selection is kept in memory at the initial use and it is used as the default detection interface unless it is changed by the user If you do not want to save the result screen press the BACK key and return to the ground balance selection screen When you press the SAVE key the following window will appear on the screen You should enter the required informatio...

Page 12: ...select the 3D RESULT tab and press the OK key There are two tabs in the archive menu These are the 3D RESULT tab and the CAMERA tab Using the right left direction keys you can select one of these tabs and you can access the CAMERA or the 3D RESULT records when you press the OK key After selecting one of the records using the up down direction keys and by pressing the OK key you can watch the video...

Page 13: ...is equipped with a special camera recorder with night vision that can be used 30 meters under water is resistant up to 4 bars of pressure and that can record at a high display quality The camera recorder can also operate on land with the same display quality During your search in difficult areas such as wells and caves filled with water lakes sea brooks water filled cisterns and tunnels you will g...

Page 14: ...ed in more detail By pressing the PAUSE button again you can continue watching the video X BUTTON X BUTTON When viewing the videos you have recorded your system is designed to display 30 frames per second fps This frame speed is the standard video format When you want to watch the video in slow motion the system offers two alternatives to the user First is the X button With the up down direction k...

Page 15: ... one of the features which makes the Golden King Deep Processor Radar unique worlwide When you turn on the SMART DETECTION system it gets activated right away and it observes all your moves until the completion of your search Due to the high display technology it uses the user can view his her moves in real time on the monitor Use of the Search Coil When designing the Golden King Deep Processor Ra...

Page 16: ...ils and the entire Golden King Deep Processor Radar system have been developed after comprehensive R D activities both electronical and chemical Thermoset engineering plastic is used on the entire system and on the Search Coils They are developed perfectly to resist the bad weather conditions such as hot cold and humid as well as water and moist Use of Additional Features Deep Search Coil 600x1000...

Page 17: ... Before doing automatic ground balancing hold the search coil about 10 centimeters above the ground and press OK With this operation your equipment will take the ground as a reference What you should do next is to raise the search coil about 40 centimeters above the ground and press the RESET button When GROUND BALANCE is selected you will see two tabs These tabs are AUTOMATIC and MANUAL ground ba...

Page 18: ...e steps depending on the mineral composition of the ground The ground balance will be completed as soon as the box completely turns to green You can switch to the search screen by pressing the OK button The system will switch to the general detection mode when you press the OK button The system will not switch to any screen until you press the OK button MANUAL GROUND BALANCE When MANUAL GROUND BAL...

Page 19: ...ction mode If you do not press the OK button the system will not switch to another screen until you press the OK button RESET BUTTON The reset button will bring all the detection settings of your system to the settings when you made the ground balance Reset should not be used when you are on the target signal Otherwise it may cause loss of depth and misinterpretation of the signal The reset operat...

Page 20: ...enu above with the right left direction keys You can save the interface you have selected by pressing the OK button Detection Functions Interface Selection The Golden King Deep Processor Radar system offers two types of detection interfaces First one is DIGITAL and the second one is GAUGE interface The user can search by selecting the interface which he she will use most conveniently These interfa...

Page 21: ...ignal received from the target in real time You will see the cavity and the mineral ratios in numbers SCOPE SCREEN During your searches with the Golden King Deep Processor Radar you will easily follow the amplitude of the the target signal in real time on the SCOPE Screen On this screen you will determine the highest amplitude point of the signal center in real time and examine the signal graph of...

Page 22: ... view of the signal On the vertical guide scale to the left of the 3D perspective image you can see the amplitude of the target signal Again on the horizontal guide scale to the left you can see the width of the scan area On the horizontal scale located at the bottom part you can see the length of the scan area Again by referring to these guide scales you can see the estimated width and length of ...

Page 23: ...ightness of the screen You can increase or decrease the brightness as you wish SENSITIVITY MENU It is for setting the depth of the system to your need Especially when ground balance is hard to achieve due to high levels of minerals in the ground reduce the sensitivity and do the ground balancing again FERROUS SETTING MENU The system allows you to search while avoiding ferrous metals nails irons bo...

Page 24: ...ion to not holding the detection coils too close to the system box Please keep your system box to the side of your body by the help of the carrying case so that the detector will not be affected Do not let the search coil come close to your shoes belt watch or any other metal object you are carrying In this presentation we have explained everything about the operation of the equipment from start u...

Page 25: ...US SETTING BY SELECTING THE ON OR OFF TAB IF YOU SELECT THE OFF TAB YOU CAN SEARCH WHILE AVOIDING FERROUS METALS YOU CAN MAKE YOUR SELECTION BY USING THE RIGHT LEFT DIRECTION KEYS TO EXIT THE MENU PRESS THE BACK KEY PLEASE SELECT THE DETECTION SCREEN USING THE RIGHT LEFT DIRECTION KEYS TO EXIT THE MENU PRESS THE BACK KEY PLEASE SELECT EITHER THE AUTOMATIC OR THE MANUAL GROUND BALANCE USING THE RIG...

Page 26: ...E BOX COMPLETELY TURNS TO GREEN IT MEANS THAT THE GROUND BALANCE IS COMPLETED SUCCESFULLY AFTERTHE GROUND BALANCE IS COMPLETED A MESSAGE INDICATING THE START AND THE END SENSITIVITY LEVELS APPEARS ON THE SCREEN NOW YOU CAN START SEARCHING BY PRESSING THE OK BUTTON THE SEARCH DISTANCE FROM THE GROUND SHOULD BE 15 20cm ABOUT 1 HAND DISTANCE WHEN A TARGET IS DETECTED PLEASE DETERMINE THE CENTER OF TH...

Page 27: ... DEPTH ON THE RESULT SCREEN YOU CAN RETURN TO THE SEARCH SCREEN BY PRESSING THE BACK KEY YOU CAN VIEW THE TARGET SIGNAL ON FULL SCREEN BY PRESSING THE 1 KEY ON THE KEYPAD ANDYOU CAN ROTATE AND EXAMINE THE SIGNAL BY USING THE 2 3 4 KEYS YOU CAN EXIT THE MENU BY PRESSING BACK YOU CAN SAVE THE RESULT SCREEN BY HOLDING THE SAVE KEY PRESSED WHEN YOU PRESS THE SAVE KEY THE SAVE WINDOW ON THE RESULT SCRE...

Page 28: ...e current technology These interpretations are for assisting the user These results are not definite They are accurate to the extent technologically feasible Data and the depth values given in the technical manual of the Golden King Deep Processor Radar system are obtained at a laboratory This data may vary on the search field Metals do not emit magnetic field by themselves unless they are excited...

Reviews: