PI Configurator
249
850-165085 / Rev.B
LED Control
This parameter can only be accessed in the
Professional
mode.
The dialogue box is used to control the behaviour of the
interfaced sensor’s internal LED during normal operation. LED
behaviour in both the charge and communication modes can not
be altered. Sensor LED parameters are:
•
Startup Only
- The LED will only illuminate (flashing its
identification code) when it is energized. It will not be turned
on during normal operation.
•
Only when Pinging
- The LED will only illuminate when it
“pings” (transmits data).
•
When <2m
- The LED will flash every time the sensor
“pings”, but only when it is at a depth of less than two
meters. This parameter is only available for depth sensors.
•
Always
- If the sensor is disabled from pinging at depths less
than two meters by the
Ping Control
parameter being set to
Depth > 2m
, the
Always
parameter causes the sensor’s LED
to illuminate at depths of less than two meters even when the
sensor does not “ping”.
Operation
To operate, use the
LED Control
spin button to select the
desired LED behaviour. Then, click the
Configure Sensor
button to program the interfaced sensor with the new parameter.
Finally, check that the message field is updated with the new
parameter, and that the message
Success!!
is displayed at the
bottom as confirmation that the command was executed.