Display modes
47
850-165085 / Rev.B
(D) = Gain indicators for the current sensors
(E) = Lower status field
(A) Numeric information
The numeric displays at the top of the
Status display
provide
the current information from the active sensors. Due to the lack
of space, the information from the sensors have been
abbreviated slightly. For a more detailed presentation, you must
select the the
Numeric display
presentation.
(B) Upper status field
The upper status field provides an overview of key parameters.
Receiver setup:
All the parameters on the left side are those
defined by the
Receiver setup
dialogue. To change these, press
the
MENU
button to access the
Setup
menu (4), and select
Receiver setup
(6).
SW:
This sentence provides the current software version in your
PI44 system.
Main
is the operational software providing the
user interface,
µ
C
is the PI44 microcontroller, while
DSP
is the
software controlling the digital signal processor, that is the
reception and interpretation of sensor information.
Max sh. speed:
This is the maximum shooting speed as defined
in the
Receiver setup
dialogue.
Demo:
This entry shows you if the sensor demonstration mode
has been activated. To switch the
Demo
mode on or off, access
the
Sensor setup.
Last received ch:
This entry shows you which of the sensors
that last provided information to the PI44.
Error:
This is simply an error code. This information is
provided for test purposes only. Unless a software error occurrs,
the code will be 0 (zero).
Hydrophone:
A yellow indicator is provided when the
hydrophone is connected and fully operational. If the indicator
is red, a short circuit has occurred. If the indicator is black, the
PI44 has lost electrical contact with the hydrophone.
NMEA1/2:
Any information accepted by the NMEA interface
will provide a green indicator. If the indicator is black, the PI44
is currently not receiving input traffic, however, information
may still be exported continuosly.