98
007-4382-002
3: Using TPM
Perform Data Consistency Operations on a LUN
When the
Perform Data Consistency Check/Restore LUN
menu selection is made, the
screen shown in Figure 3-62 appears.
Figure 3-62
Data Consistency Check/Restore
Note:
A check consistency will pause any background initialization process.
Background initialization will not restart until a write is sent to the LUN against which
background initialization was paused.
Use this screen to initiate a check and/or repair on a logical drive. To execute this process,
the logical drive must be configured for high-availability RAID.
There are several reasons why the check or restore could be denied, and TPM reports the
reasons if the request is rejected. The most common reasons are that there is no on-line
spare disk to be used to repair the LUN, or more than one rebuild at a time is being
attempted.