2: Setup and Operation
Connecting the Power Cord
To connect a power cord to power supply modules, follow these steps:
1.
For redundant configurations, attach the bifurcated power cord to the power supply
modules.
2. Attach the power cord to the in-line IEC connector.
Note:
These power-splitting cables are provided so that the system is operated from
a single power source, thus providing a single point of disconnect.
A standby LED on the ESI/Ops panel indicates whether AC power is present.
For non-redundant systems using one power supply module, connect the power cord to
the power supply module and to the power source.
Perform these checks to ensure that a safe grounding system is provided:
1.
If a rack distribution system is being used, perform these tasks:
–
Ensure power is removed from the rack.
–
Connect the supplied power cord to the rack distribution and the enclosure.
2. If a direct connection is made with the power cord, ensure that it is connected to the
enclosure.
Caution:
Some electrical circuits could be damaged if external signal cables or power
control cables are present during the grounding checks.
3. Check for continuity between the earth pin of the power cord on one of the power
supply modules (or rack inlet) and any exposed metal surface of the SGI TP900
enclosure.