Overview
007-4428-003
43
Table 4-1 summarizes the functions of the LEDs on the ESI/Ops panel and refers to the
sections that cover specific component failures.
The following sections explain how to troubleshoot initial startup problems, system
faults, power supply faults, and cooling module faults.
Table 4-1
ESI/Ops LED States
LED
LED State and Meaning
See This Section
System
status
Green signifies that power is applied to the enclosure.
Amber signifies that the ESI processor has failed.
“System Faults”
on page 45
Power
status
Green signifies that the power supplies are functioning normally.
Amber signifies that there is a PSU failure in a dual-PSU enclosure.
In the event of a PSU failure in a single-PSU enclosure, all LEDs are off.
“Power Supply
Faults” on
page 45
Cooling
status
Green signifies that all fans are functioning normally.
Amber signifies that there is a fan failure.
“Cooling
Module Faults”
on page 46