Table 4-2 explains how to troubleshoot a system status LED that is amber.
Power Supply Faults
Table 4-3 explains how to troubleshoot a power supply module status LED that is amber.
Table 4-2
System Faults
Symptom
Cause
Action
The system
LED is amber.
The ESI processor has
detected an internal
fault.
1. Check for other amber LED indicators on the power
supply modules. If there is a PSU error, there may be a
communications problem with that power supply
module. Remove and then re-fit the module. If the
problem persists, change the module.
2. Check for other amber LED indicators on the drive
carriers. If none are evident, there may be either an ESI
processor problem or a backplane problem.
Table 4-3
Power Supply Faults
Symptom
Cause
Action
Operator panel power
supply LED is amber.
OR
One or more power
supply module LEDs
are amber.
Any power
fault.
1. Check that the AC power connection to the power
supply module is live.
2. Check that the power supply module is switched on.
3. Disconnect the power supply module from AC
power, remove the module from the system, and then
re-install it. If the problem persists, replace the power
supply module.