69
Siemens Building Technologies
Fire Safety & Security Products
08.2006
NOTE
If necessary, refit the dust cap attached to the lanyard - to avoid corrosion of the connector terminals.
5.
Unhook the Dome from its mounting bracket.
13.2 Monthly
checks
z
Visually check the mounting bracket for signs of defect or corrosion.
z
Check the cable runs between the Dome unit and External Telemetry Unit for
security of attachment and signs of wear.
z
Check all mechanical fixings to the building infrastructure for corrosion, wear and
rigidity.
z
Issue the customer a written report of any defects (which are beyond the scope
of CCTV maintenance) in the building infrastructure or other equipment.
z
Check that the Solaris™ Dome / camera is functioning correctly for:
–
Full range of movement, bearing in mind any ‘soft limits’ that may have been
set.
–
Slow and fast speeds.
–
Picture quality.
z
Clean the bubble if necessary. See ‘Bubble Maintenance'.
z
Check fan speed (Diagnostic menu). Although the fan speed changes
depending on temperature, it should always run above 50% speed.
z
Perform camera lens initialise, followed by a camera reset. See Reset menu in
Section 11.1.2: The Camera menu.
13.3 Bubble
maintenance
z
When handing the bubble, always hold the outer flange if possible. Handle with
extreme care as the bubble is easily scratched.
z
Under no circumstances should you touch the inner surface of the bubble.
z
If debris is present on the inner surface,
do not
wipe it with a cloth. Blow the
debris out of the bubble using a filtered air line or a can of compressed air
(available from electronics suppliers, e.g. RS).
z
Small scratches or scuffs can be removed from the outer surface with the use of
a suitable cloth and metal polish (brass cleaner).
Summary of Contents for Solaris CCDS1415-DN