21
Siemens Building Technologies
Fire Safety & Security Products
08.2006
8.3.5
Pole fixture (using wall mount CCDS1415-WM)
The wall mount CCDS1415-WM has four 12 mm square holes through the
mounting plate. These holes are to pass 11 mm continuous banding through as
shown.
NOTE
Ensure the chosen fasteners and fastening method are suitable for the application and the mounting
substrate.
Fig. 11
Pole mounting
8.3.6 Recessed
ceiling
tile mount CCDS1415-FM
The Solaris™ Dome can be installed in a standard false ceiling tile using the
recessed ceiling tile mount. The recessed ceiling tile mount consists of two
accessory mounting brackets that are fixed to the Solaris™ Dome, and two U-
channel brace bars which are secured to the ceiling support framework. The brace
bars are suitable for use with both 600x600 mm and 600x1200 mm ceiling tile
systems.
To install the recessed ceiling tile mount you will need access to the top of the tile
from one or more adjacent tiles.
Install using the recessed ceiling tile mount as follows:
1.
Prepare the ceiling tile by cutting a 235 mm diameter hole in the centre (using
the template provided) and then fit it back in place in the ceiling support
frame.
2.
Remove the six screws holding the Solaris™ Dome's bezel in place and
remove the bezel.
NOTE
Handle the bubble of the Solaris™ Dome with extreme care and be sure not to scratch it, as this may
affect its optical clarity.
3.
Fit the ceiling mount accessory brackets in place using the four self-tapping
screws provided.