39
Siemens Building Technologies
Fire Safety & Security Products
08.2006
10
Configuration of the External Termination Unit
Once the physical installation of the XTU is complete it needs to be configured to
use the correct telemetry protocol and receiver address to identify itself correctly.
To allow this to be carried out, the XTU is fitted with a LCD display and a simple
keyboard.
By default, the display indicates the receiver address, the current protocol and the
interface that is in use. However, the keypad can be used to control a menu
system that provides access to a number of settings.
Fig. 17
XTU keyboard
10.1 Keys and their functions
Keys Functions
Used to enter a menu or select an option.
Scrolls through the available options.
Navigates between options.
NOTE
The left key allows you to go back up a level in the menus.
Switches the display into ‘live video’ mode for test purposes.
NOTE
Camera control is not possible when in LCD ‘live video’ mode.
Press the
button when in ‘live video’ mode to enter pan and tilt mode, where
the Dome can be controlled via the XTU. Pressing it again allows zoom and focus,
pressing a 3rd time switches back to ‘live video’ mode.
Pressing the
button will exit this mode; alternatively this mode will exit after 2
minutes of inactivity.
NOTE
Whilst in this mode, pressing the Up or Down keys will alter the brightness of the LCD display.