50
Siemens Building Technologies
Fire Safety & Security Products
08.2006
11.1.5 The Soft Limits and Sectors menu
Soft limits
The Soft Limits menu will allow you to set up and remove programmable soft limits
to the vertical travel of the camera.
Once the upper and lower limits are set, the camera will not view the areas above
or below those limits.
Sectors
The Solaris™ Dome’s horizontal movement is divided into 16 sectors that can be
individually identified with a name. The Sectors item will allow you to configure the
names of the sectors.
When the sector function is activated (in the OSD menu, see Section 11.1.7), the
sector name is displayed on screen whenever the camera is looking into that
sector. The purpose of this is to provide the operator with help in orientation. The
Edit Sector menu allows you to edit the sector name.
For example: North >> East >> South >> West
LIMITS AND SECTORS
SET UPPER SOFT LIMIT
SET LOWER SOFT LIMIT
CLEAR SOFT LIMIT
1
SECTORS
BACK
SECTOR MENU
SECTOR NUMBER...1-
16
(Set Name)
4
CLEAR NAME
COPY
PASTE
HELP
BACK
STORE LOWER SOFT LIMIT³
STORE
ABORT
STORE UPPER SOFT LIMIT²
STORE
ABORT
Fig. 24
The SOFT LIMITS AND SECTORS menu
1
) Press ‘Set’ to delete the current soft limit settings.
2
) Use the joystick to tilt to the desired position. Select store to save the limit or
abort to exit without saving.
3
) Use the joystick to tilt to the desired position. Select store to save the limit or
abort to exit without saving.
4
) Each sector can have up to 24 characters of text assigned to it. If blank, the
whole line is highlighted, press ‘Set’ to add characters.
Summary of Contents for Solaris CCDS1415-DN
Page 73: ......