data
4.1 Dome
Electrical
Camera types
18x optical Colour (PAL): CCDS1415-ST
18x optical Day/Night (PAL): CCDS1415-DN
26x optical Day/Night (PAL): CCDS1415-DNX
Input voltage XTU
110 – 230 V AC @ 50 / 60 Hz, 1 A max.
In-rush current XTU
40 A / 20 A peak @ 110 / 230 V AC
Input voltage Dome unit
18-24 V DC @ 2 amp, supplied from the XTU via the
Cat-5 cable
Connections
Video:
BNC
coax
Power: Screw terminal block
Telemetry: C type(Coax): BNC
D type (Twisted Pair): Screw terminal block
Alarm: Screw terminal block
Relay: Screw terminal block
Photon: Screw terminal block
Electromagnetic
compatibility
Compliant with EMC directive 89/336/EC.
Conforms to Part 15 of the FCC Rules, Class A digital
device
Operational
Pan
speed
0.2-360°/sec
Pan
travel
360°
continuous
Tilt
speed
0.2-360°/sec
Tilt travel
+10° and -100°
Presets
99
Tours
32 positions, fully programmable for sequence, dwell and
speed
Preset
accuracy
0.3°
Control hardware
SIMATRIX NEO, SIMATRIX SYS/648/164 via CAC0103,
CKA3210, CKA4820, SISTORE AX, CX, MX, SX,
Visilynx V3i, Visilynx II, Visilynx 2+, 6000 series, 600
series,
XTU video output
Nominal (no gain) VBS 1.0 Vp-p (sync negative)
Relay contact rating
1.5 A @ 24 V DC
Alarm input
Opto-coupled (short to alarm com.)
Mechanical
Application
Indoor or outdoor - all models
Mounting
Wall/fixed ceiling, corner, wall top, pendant, pole, swan
neck or ceiling tile
Pendant mount size/thread Standard 1.5” BSP (parallel)
Weight
Boxed 5.6 kg, XTU only (no cables) 1.5 kg, DOME UNIT
only (no cables) 2.5 kg
Ext. construction
Injection moulded polycarbonate (GE Lexan EXL9335)
Colour
Pure
white
RAL9010
Bubble
Smoked:
CCDS1415-ST
Clear:CCDS1415-DN / -DNX