Appendix
A.8 Information List
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
743
10294
U2>(>) TRIP command (U2>(>)
TRIP)
Voltage Prot.
OUT
*
on
*
LED
BO
73
94
2
Yes
10300
U1< Pickup (U1< Pickup)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
100
2
Yes
10301
U1<< Pickup (U1<< Pickup)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
101
2
Yes
10302
U1< TimeOut (U1< TimeOut)
Voltage Prot.
OUT
*
*
*
LED
BO
10303
U1<< TimeOut (U1<< TimeOut)
Voltage Prot.
OUT
*
*
*
LED
BO
10304
U1<(<) TRIP command (U1<(<)
TRIP)
Voltage Prot.
OUT
*
on
*
LED
BO
73
104
2
Yes
10310
Uph-e< Pickup (Uph-e< Pickup)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
110
2
Yes
10311
Uph-e<< Pickup (Uph-e<<
Pickup)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
111
2
Yes
10312
Uph-e<(<) Pickup L1 (Uph-e<(<)
PU L1)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
112
2
Yes
10313
Uph-e<(<) Pickup L2 (Uph-e<(<)
PU L2)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
113
2
Yes
10314
Uph-e<(<) Pickup L3 (Uph-e<(<)
PU L3)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
114
2
Yes
10315
Uph-e< TimeOut (Uph-e< Time-
Out)
Voltage Prot.
OUT
*
*
*
LED
BO
10316
Uph-e<< TimeOut (Uph-e<< Tim-
eOut)
Voltage Prot.
OUT
*
*
*
LED
BO
10317
Uph-e<(<) TRIP command (Uph-
e<(<) TRIP)
Voltage Prot.
OUT
*
on
*
LED
BO
73
117
2
Yes
10318
Uph-e< Pickup L1 (Uph-e< PU
L1)
Voltage Prot.
OUT
*
*
*
LED
BO
73
145
2
Yes
10319
Uph-e< Pickup L2 (Uph-e< PU
L2)
Voltage Prot.
OUT
*
*
*
LED
BO
73
146
2
Yes
10320
Uph-e< Pickup L3 (Uph-e< PU
L3)
Voltage Prot.
OUT
*
*
*
LED
BO
73
147
2
Yes
10321
Uph-e<< Pickup L1 (Uph-e<< PU
L1)
Voltage Prot.
OUT
*
*
*
LED
BO
73
148
2
Yes
10322
Uph-e<< Pickup L2 (Uph-e<< PU
L2)
Voltage Prot.
OUT
*
*
*
LED
BO
73
149
2
Yes
10323
Uph-e<< Pickup L3 (Uph-e<< PU
L3)
Voltage Prot.
OUT
*
*
*
LED
BO
73
150
2
Yes
10325
Uph-ph< Pickup (Uph-ph<
Pickup)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
125
2
Yes
10326
Uph-ph<< Pickup (Uph-ph<<
Pickup)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
126
2
Yes
10327
Uphph<(<) Pickup L1-L2 (Uph-
ph<(<)PU L12)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
127
2
Yes
10328
Uphph<(<) Pickup L2-L3 (Uph-
ph<(<)PU L23)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
128
2
Yes
10329
Uphph<(<) Pickup L3-L1 (Uph-
ph<(<)PU L31)
Voltage Prot.
OUT
*
on off
*
LED
BO
73
129
2
Yes
10330
Uphph< TimeOut (Uphph< Time-
Out)
Voltage Prot.
OUT
*
*
*
LED
BO
10331
Uphph<< TimeOut (Uphph<<
TimeOut)
Voltage Prot.
OUT
*
*
*
LED
BO
10332
Uphph<(<) TRIP command (Uph-
ph<(<) TRIP)
Voltage Prot.
OUT
*
on
*
LED
BO
73
132
2
Yes
10333
Uph-ph< Pickup L1-L2 (Uphph<
PU L12)
Voltage Prot.
OUT
*
*
*
LED
BO
73
151
2
Yes
10334
Uph-ph< Pickup L2-L3 (Uphph<
PU L23)
Voltage Prot.
OUT
*
*
*
LED
BO
73
152
2
Yes
No.
Description
Function
Type
of In-
for-
matio
n
Log Buffers
Configurable in Matrix
IEC 60870-5-103
Ev
ent Log
O
N
/O
FF
T
rip (
F
aul
t)
Log On/
O
ff
G
round
Fault Log ON/
O
FF
M
a
rk
e
d
i
n
O
s
ci
ll.
Re
c
o
rd
LED
B
ina
ry
I
n
pu
t
Function
Key
Rela
y
Chatte
r Suppr
e
ssion
Ty
p
e
In
form
ati
on Nu
mbe
r
Dat
a
Un
it
Ge
ne
ra
l Int
e
rro
ga
ti
on