Other ambient conditions
Table B-6
Other ambient conditions
Storage with suitable packag‐
ing
Transport with suitable pack‐
aging
Operation
Biological ambient conditions
according to class
1B1 according to DIN EN
60721‑3‑1 (IEC 60721‑3‑1)
2B1 according to DIN EN
60721‑3‑2 (IEC 60721‑3‑2)
3B1 according to DIN EN
60721‑3‑3 (IEC 60721‑3‑3)
(without harmful flora)
Chemically active substan‐
ces according to class
1C1 according to DIN EN
60721‑3‑1 (IEC 60721‑3‑1)
2C1 according to DIN EN
60721‑3‑2 (IEC 60721‑3‑2)
3C1 according to DIN EN
60721‑3‑3 (IEC 60721‑3‑3)
Mechanically active substan‐
ces according to class
1S1 according to DIN EN
60721‑3‑1 (IEC 60721‑3‑1)
2S1 according to DIN EN
60721‑3‑2 (IEC 60721‑3‑2)
3S1 according to DIN EN
60721‑3‑3 (IEC 60721‑3‑3)
B.1.4
Technical specifications of the common power supply
Table B-7
Technical specifications of the common power supply
Rated voltage U
Erated
/ rated input frequency f
Erated:
1-phase 115 VAC / 60 Hz
1-phase 230 VAC / 50 Hz / 60 Hz
1-phase 240 VAC / 50 Hz / 60 Hz
Peak value of the rated output voltage U
Arated
:
55 V ±3%
Rate of rise of voltage (dv
a
/dt)
max
:
2 kV/μs
Rated output frequency f
Arated
:
100 kHz ±5%
Natural convection
,
T
Env
= 55° C, P
A1Rated
:
87.5 W for UE
RATED
=
230 V
75 W for UE
RATED
= 115 V
Rated total power output with natural convection
,
T
Env
= 55° C,
P
A1Rated
:
350 W for UE
RATED
= 230 V 300 W for UE
RATED
=
115 V
Possible load duty cycle
Transient, 60 s - 1.2 x P
ARated
Recovery time
30 minutes
Mean value of output current per half-period per output, I
ARated
:
1.25 A
Peak value of output current during rated operation per output, I
Amax
: Approx. 6.5 A
Switch-off overcurrent limit value per output, I
Aoff
:
10 A
Efficiency under rated conditions
η > 80%
B.1.5
Technical specifications of the diagnostics module DM10
Table B-8
Technical specifications of the AD586LR reference element
Version
AD586LR
Output voltage
5 V ±2.5 mV
Deviation of the output voltage for 0° C up to 70° C
5 ppm/°C
Technical data and drawings
B.1 Technical specifications
SINAMICS SM150 6SL3845-7NN46-7AA0
200
Operating Instructions 04/2017
Summary of Contents for SINAMICS SM150
Page 2: ...20 04 2017 13 53 V27 00 ...
Page 14: ...Table of contents SINAMICS SM150 6SL3845 7NN46 7AA0 14 Operating Instructions 04 2017 ...
Page 122: ...Start up SINAMICS SM150 6SL3845 7NN46 7AA0 122 Operating Instructions 04 2017 ...
Page 190: ...Maintenance 9 7 Repairs SINAMICS SM150 6SL3845 7NN46 7AA0 190 Operating Instructions 04 2017 ...
Page 192: ...Spare parts SINAMICS SM150 6SL3845 7NN46 7AA0 192 Operating Instructions 04 2017 ...
Page 196: ...Service Support SINAMICS SM150 6SL3845 7NN46 7AA0 196 Operating Instructions 04 2017 ...
Page 217: ......