3.5.12.2
Measuring socket assignment
The process data acquisition system (PADU8) is used for the diagnosis of analog and digital
converter signals. The process data acquisition system is designed as an optional component.
If the PADU8 is not included, the signals can be read out with the aid of an oscilloscope, for
example, at measuring sockets.
Figure 3-8
Printed circuit board of the diagnostics module
Measuring sockets
Signal
Measuring sockets
Signal
X20/X28 or X29
AO_0
X26/X28 or X29
AO_6
X21/X28 or X29
AO_1
X27/X28 or X29
AO_7
X22/X28 or X29
AO_2
X14/X18 or X19
DO_4
X23/X28 or X29
AO_3
X15/X18 or X19
DO_5
X24/X28 or X29
AO_4
X16/X18 or X19
DO_6
X25/X28 or X29
AO_5
X17/X18 or X19
DO_7
3.5.12.3
Interface description of the connectors
The individual module elements of the DM10 diagnosis module supply several interfaces. The
interfaces are occupied by the following connectors:
X231
PSA connection
X232
PSA connection
X1
PADU8 connection (option G66)
X5
PADU8 connection (option G66)
X31
Closed-loop control interface
X32
Closed-loop control interface
X33
Binary process diagnosis with PADU8 (option G66)
X34
Closed-loop control interface
Description
3.5 Description of the components
SINAMICS SM150 6SL3845-7NN46-7AA0
44
Operating Instructions 04/2017
Summary of Contents for SINAMICS SM150
Page 2: ...20 04 2017 13 53 V27 00 ...
Page 14: ...Table of contents SINAMICS SM150 6SL3845 7NN46 7AA0 14 Operating Instructions 04 2017 ...
Page 122: ...Start up SINAMICS SM150 6SL3845 7NN46 7AA0 122 Operating Instructions 04 2017 ...
Page 190: ...Maintenance 9 7 Repairs SINAMICS SM150 6SL3845 7NN46 7AA0 190 Operating Instructions 04 2017 ...
Page 192: ...Spare parts SINAMICS SM150 6SL3845 7NN46 7AA0 192 Operating Instructions 04 2017 ...
Page 196: ...Service Support SINAMICS SM150 6SL3845 7NN46 7AA0 196 Operating Instructions 04 2017 ...
Page 217: ......