3.5.8
Power Stack Adapter
The Power Stack Adapter (PSA) acts as the physical interface between the power unit and
the open-loop/closed-loop controller. This is where the galvanic isolation (electrical coupling
via light) between the power unit and the open-loop controller takes place. Data is exchanged
between the Power Stack Adapter and the Control Unit via the DRIVE-CLiQ high-speed serial
communication interface.
①
X11 – X14
Gating of the power semiconductors, inverter phase u
②
X15, X16,
Gating of the power semiconductors, crowbar
③
X31 – X34
Gating of the the power semiconductors, inverter phase v
④
X35, X36
Gating of the power semiconductors, braking chopper
⑤
X51 – X54
Gating of the power semiconductors, inverter phase w
⑥
X241, X242
Selecting Safe Torque Off
⑦
X70 – X79
Actual value channels 0 to 9
⑧
X81
Trip line
⑨
X200 – X202
DRIVE-CLiQ interfaces
⑩
X231, X232
Analog and digital outputs
⑪
S5.0
S5.1
Switches of the analog inputs, voltage/current measurement AI0
Switches of the analog inputs, voltage/current measurement AI1
⑫
X221, X222
Analog and digital inputs, temperature sensor connections
⑬
LEDs
Diagnostics via LEDs
⑭
X210
Electronics power supply
Figure 3-3
Overview of PSA interfaces
Description
3.5 Description of the components
SINAMICS SM150 6SL3845-7NN46-7AA0
38
Operating Instructions 04/2017
Summary of Contents for SINAMICS SM150
Page 2: ...20 04 2017 13 53 V27 00 ...
Page 14: ...Table of contents SINAMICS SM150 6SL3845 7NN46 7AA0 14 Operating Instructions 04 2017 ...
Page 122: ...Start up SINAMICS SM150 6SL3845 7NN46 7AA0 122 Operating Instructions 04 2017 ...
Page 190: ...Maintenance 9 7 Repairs SINAMICS SM150 6SL3845 7NN46 7AA0 190 Operating Instructions 04 2017 ...
Page 192: ...Spare parts SINAMICS SM150 6SL3845 7NN46 7AA0 192 Operating Instructions 04 2017 ...
Page 196: ...Service Support SINAMICS SM150 6SL3845 7NN46 7AA0 196 Operating Instructions 04 2017 ...
Page 217: ......