8.4.2.2
Digital outputs
The drive is equipped with four bidirectional digital outputs (terminal X541) and two relay
outputs (terminal X542). These outputs are, for the most part, freely parameterizable. For
details, please refer to the circuit manual of the drive.
List of signals for the digital outputs
Signal
Bit in status word 1 Parameter
1 = Ready to switch on
0
r0889.0
1 = Ready to operate (DC link loaded, pulses blocked)
1
r0889.1
1 = Operation enabled (drive follows n_set)
2
r0889.2
1 = Fault present
3
r2139.3
0 = Coast to stop active (OFF2)
4
r0889.4
0 = Fast stop active (OFF3)
5
r0889.5
1 = Power-on disable
6
r0889.6
1 = Alarm present
7
r2139.7
1 = Speed setpoint/actual deviation in the tolerance bandwidth
(p2163, p2166)
8
r2197.7
1 = Control required to PLC
9
r0899.9
1 = f or n comparison value reached or exceeded (p2141, p2142) 10
r2199.1
1 = I, M, or P limit reached (p0640, p1520, p1521)
11
r1407.7
Reserved
12
0 = Alarm motor overtemperature (A7910)
13
r2129.14
Reserved
14
0 = Alarm thermal overload in power unit (A5000)
15
r2129.15
1 = Pulses enabled (inverter is clocking, drive is carrying current)
r0899.11
1 = n_act ≤ p2155
r2197.1
1 = n_act > p2155
r2197.2
1 = Ramp-up/ramp-down completed
r2199.5
1 = n_act < p2161 (preferably as n_min or n=0 message)
r2199.0
1 = Torque setpoint < p2174
r2198.10
1 = LOCAL mode active (control via operator panel)
r0807.0
0 = Motor blocked
r2198.6
1 = Ready to switch on
0
r0889.0
Operation
8.4 Functions
SINAMICS SM150 6SL3845-7NN46-7AA0
Operating Instructions 04/2017
137
Summary of Contents for SINAMICS SM150
Page 2: ...20 04 2017 13 53 V27 00 ...
Page 14: ...Table of contents SINAMICS SM150 6SL3845 7NN46 7AA0 14 Operating Instructions 04 2017 ...
Page 122: ...Start up SINAMICS SM150 6SL3845 7NN46 7AA0 122 Operating Instructions 04 2017 ...
Page 190: ...Maintenance 9 7 Repairs SINAMICS SM150 6SL3845 7NN46 7AA0 190 Operating Instructions 04 2017 ...
Page 192: ...Spare parts SINAMICS SM150 6SL3845 7NN46 7AA0 192 Operating Instructions 04 2017 ...
Page 196: ...Service Support SINAMICS SM150 6SL3845 7NN46 7AA0 196 Operating Instructions 04 2017 ...
Page 217: ......