6.3.6
Terminal box 1XB7750
Figure 6-7
Terminal box 1XB7750
The connecting cables are introduced into the 1XB7750 terminal box through the cable glands
with threaded holes 8 x M72 x 2 and 3 x M25 x 1.5. The cable glands are not included in the
standard scope of supply.
You can find additional information here:
● Bringing cables into the terminal box 1XB... with cable gland (Page 93)
● Connecting cables with cable lugs (Page 95)
● Connecting cables without cable lugs (Page 96)
6.3.7
Rotating the terminal box
Depending on the terminal box and version, you can rotate the terminal box through ±90° in
accordance with the connection direction. The implementation on the other motor side is
possible only with the support of the Service Center (Page 177). If you want to rotate a terminal
box not listed below, then also contact the Service Center.
Rotating the terminal box depends on the mount and the cross-section of the internal stator
cables as well as the terminal box type:
● 1XB7730
– With installed internal stator cables, you can rotate the terminal box through ±90°.
● 1XB7731
– For six or fewer cables, you can rotate the terminal box with installed stator cables
through ±90°.
– For more than six cables, you must remove the internal stator cables before rotation.
Electrical connection
6.3 Terminal box
SIMOTICS FD 1MH1
Operating Instructions 08/2017
85
Summary of Contents for SIMOTICS FD 1LL1
Page 2: ...18 08 2017 17 24 V10 00 ...
Page 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Page 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Page 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Page 187: ......