5.4
Connecting the cooling water supply
There are three couplings
①
and
②
on the bearing shield for the coolant connection. The
lower coupling
②
is used to drain the coolant for type of construction IM B3.
Figure 5-5
Standard coolant connections and coolant drain hole
1. With the "Piping" option, piping is attached on the right, left or top at the NDE. You can then
connect the coolant supply radially to the appropriate side.
Different threads are available depending on the machine type.
Machine type
Thread
1LH….-3A…-…. / 1MH….-3A…-….
1LH….-3B…-…. / 1MH….-3B…-….
G1/2"
1LH….-4A…-…. / 1MH….-4A…-….
1LH….-4B…-…. / 1MH….-4B…-….
G3/4"
2. Only use valves, fittings and cooling water pipes made of rust-proof, stainless steel in the
cooling system.
3. Make sure that the cooling water complies with the required cooling water specification.
4. Make sure that the appropriate volume of cooling water is available.
Assembly
5.4 Connecting the cooling water supply
SIMOTICS FD 1MH1
Operating Instructions 08/2017
77