Rotors
The rotor assembly is pressed onto the shaft together with the cage winding. The drive end of
the shaft usually has a cylindrical shaft end. Dependent on the design, a second shaft end
may be located at the non-drive end.
Drive
The motor speed is controlled using a converter. It has been optimized for operation with
SINAMICS low-voltage converters.
Other converters must comply with certain requirements: You can find more information in the
catalog or in the engineering documentation.
Line operation
The motor is supplied from the line system.
NOTICE
Destruction of the machine when operated directly from the line supply
The machine will be destroyed if it is directly connected to the line supply. Only operate the
machine using a converter.
NOTICE
Machine damage for operation on the converter
If you connect the machine to a converter, the machine can be damaged. Operate the
machine only on the electrical supply system.
Cooling
The cooling system is designed as a closed, internal cooling circuit. The heat lost from the
machine is dissipated partially via heat conduction and partially via the cooling air at the cooling
water flowing through the cooling pipes. A shaft-mounted fan ensures circulation of the cooling
air.
Degree of protection
The machine is available with degree of protection IP55.
Description
3.1 Comparison of IEC and GOST standards
SIMOTICS FD 1MH1
Operating Instructions 08/2017
29
Summary of Contents for SIMOTICS FD 1LL1
Page 2: ...18 08 2017 17 24 V10 00 ...
Page 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Page 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Page 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Page 187: ......