8.7
Decommissioning the machine
NOTICE
Damage as a result of an extended period out of service
If the machine is going to be out of service for longer than six months, then take the necessary
measures for preservation and storing. Otherwise damage to the machine will result.
Record the decommissioning steps. This log will be useful upon recommissioning.
8.8
Switching off the water-cooling system
Do not immediately switch off the water-cooling system after switching off the machine. First
wait for the machine to cool down. This will prevent the accumulation of residual heat.
8.9
Draining the coolant
If you take the machine out of service, drain the coolant if this is necessary for the ambient
conditions.
Type of construction IM B3
Use the coolant drain hole
②
in the bearing shield to drain the coolant.
①
Coolant connection
②
Coolant connection and coolant drain hole
Operation
8.7 Decommissioning the machine
SIMOTICS FD 1MH1
Operating Instructions 08/2017
127
Summary of Contents for SIMOTICS FD 1LL1
Page 2: ...18 08 2017 17 24 V10 00 ...
Page 176: ...Disposal 11 4 Disposal of components SIMOTICS FD 1MH1 176 Operating Instructions 08 2017 ...
Page 178: ...Service and Support SIMOTICS FD 1MH1 178 Operating Instructions 08 2017 ...
Page 182: ...Quality documents SIMOTICS FD 1MH1 182 Operating Instructions 08 2017 ...
Page 187: ......