Mechanical ambient conditions
The following table shows the mechanical ambient conditions in the form of sinusoidal
vibrations.
Table 9-10
Mechanical ambient conditions
Frequency range in Hz
5 ≤ f ≤ 8.4
Amplitude 3.5 mm
8.4 ≤ f ≤ 150
constant acceleration 9.8 m/s
2
Reduction of vibration
If the described components are subject to big shock or vibration, appropriate measures must
be taken to reduce the acceleration or the amplitude.
We recommend mounting the described components on damping materials (rubber-metal anti-
vibration mountings, for example).
Tests of mechanical ambient conditions
The following table provides important information with respect to the type and scope of the
tests of mechanical ambient conditions.
Table 9-11
Tests of mechanical ambient conditions
Condition tested
Test standard
Comment
Vibration
Vibration test according to
IEC 60068‑2‑6 (sinusoidal)
Type of vibration:
● Frequency sweeps with a rate of change of 1 octave/minute.
– 5 Hz ≤ f ≤ 8.4 Hz,
constant amplitude 3.5 mm
– 8.4 Hz ≤ f ≤ 150 Hz,
constant acceleration 9.8 m/s
2
Duration of vibration:
● 10 frequency sweeps per axis at each of three vertically aligned
axes
Shock
Shock, tested according to
IEC 60068‑2‑27
Type of shock:
● Half-sine
Shock intensity
1)
:
● Peak value 150 m/s
2
● Duration 11 ms
Direction of shock:
● 3 shocks in each direction (+/-) at each of three vertically aligned
axes
1)
Note that I/O modules with relay contacts are tested and approved in accordance with the relay manufacturer’s
specifications. You can find further information in the documentation of I/O module with relay contacts.
Technical specifications
9.4 Mechanical and climatic environmental conditions
ET 200SP HA Distributed I/O system
144
System Manual, 08/2019, A5E39261167-AD
Summary of Contents for SIMATIC ET 200SP HA
Page 6: ...Table of contents ET 200SP HA Distributed I O system 6 System Manual 08 2019 A5E39261167 AD ...
Page 181: ...Glossary ET 200SP HA Distributed I O system System Manual 08 2019 A5E39261167 AD 181 ...
Page 182: ...Glossary ET 200SP HA Distributed I O system 182 System Manual 08 2019 A5E39261167 AD ...