Maintenance
9.2 Replacement of I/O modules and front connectors
ET 200MP Distributed I/O System
88
System Manual, 01/2013, A5E03723484-01
9.2.2
Replacing an I/O module
Introduction
When the front connector is first inserted into the I/O module, a part of the coding element
clips onto the front connector. When you replace an I/O module with the same type of
module, the correct coding element is already present in the front connector.
Replacing an I/O module
You have already disconnected the I/O module:
1.
With a new I/O module, use a screwdriver to break out the half of the coding element that
is designated for the front connector.
Figure 9-3
Breaking the coding element out of the I/O module
2.
Insert the old front connector into the new I/O module (same module type), until your hear
it click into place.