5.1.3.2.1 Connecting
When connecting to a measurement device, it makes a difference which of several situations is in effect:
1. Device is in rest state:
Connection is carried out.
2. Device has been disconnected from the PC during a running measurement
A dialog prompts the user to decide whether to connect during the running measurement or to stop the
measurement.
When connecting to the running measurement, the currently open measurement configuration is closed and
the configuration required by the device is read and loaded. The program connects to the device and goes into
measurement mode. If the required measurement configuration is not found, the process can be aborted. The
device continues to carry out measurements without any connection having been made.
If the user chooses to stop measurement in order to set up the connection, the current measurement
configuration remains open and unchanged.
3. The device was previously disconnected in an uncontrolled manner
The user is notified that connection is only possible after first stopping measurement. If the process is aborted,
the device continues measuring without any connection having been made.
4. Measurement device takes measurements after an automatic start
Same procedure as under Point 2 above.
5.1.3.2.2 Test start
To check your settings, it's possible to perform a test measurement. In this case, measured
data are not saved. Click on the
online monitoring
to view the data measured.
One-time triggering and transmission of messages. Strongly recommended for verifying the
connection parameters entered.
has been defined and the device was prepared.