Operation modes and settings
Power Quality Recorder SICAM Q80 7KG8080, System manual
E50417-H1076-C420-A2, Release 12.01.2015
5.1.2.3.1.3 Event overview - Which value limit affects what
Text-
Notification
DO-output
Message
(SMS, Email)
Data recording
LED
Value limits for event messages
Voltage events
x
x
x
-
-
THD
x
x
-
-
-
Asymmetry
x
x
-
-
-
Frequency
x
-
-
-
-
Available memory
x
x
x
-
x
Harmonics
x
x
-
-
-
Power
x
x
-
-
-
Poqwe factor
x
x
-
-
-
Value limits for triggering
Voltage
x
x
-
x
x
Current
x
x
-
x
x
Frequency
x
x
-
x
x
Signal frequency
x
-
-
x
x
Digital input
DI 1..4
x
-
-
x
x
Miscellaneous
System error
-
x
-
-
x
Device active
-
-
-
-
x
Network trigger
-
x
-
x
x
Time synchronization
x
x
-
-
x
Frequency measurable
x
-
-
-
x
5.1.2.3.2 Events
Cutoff values for event messages
Here, the value limits for all messages are entered. These are independent of the standard used in the evaluation.
To load the defaults for the standard EN50160, click on the button
Set defaults for EN 50160
.
The events defined here are available for selection under
.