Semiconductor Group
165
Instruction Set
JC
rel
Function:
Jump if carry is set
Description:
If the carry flag is set, branch to the address indicated; otherwise proceed with the
next instruction. The branch destination is computed by adding the signed relative-
displacement in the second instruction byte to the PC, after incrementing the PC
twice. No flags are affected.
Example:
The carry flag is cleared. The instruction sequence
JC
LABEL1
CPL
C
JC
LABEL2
will set the carry and cause program execution to continue at the instruction
identified by the label LABEL2.
Operation:
JC
(PC)
←
(PC) + 2
if (C) = 1
then (PC)
←
(PC) + rel
Bytes:
2
Cycles:
2
Encoding:
0 1 0 0
0 0 0 0
rel. address
*
Summary of Contents for SAB 80515 Series
Page 9: ...Semiconductor Group 9 Introduction Figure 1 2 Block Diagram ...
Page 12: ...Semiconductor Group 12 Fundamental Structure Figure 2 1 Detailed Block Diagram ...
Page 18: ...Semiconductor Group 18 Central Processing Unit Figure 3 1 Fetch Execute Sequence ...
Page 73: ...Semiconductor Group 73 On Chip Peripheral Components Figure 7 25 A D Converter Block Diagram ...
Page 83: ...Semiconductor Group 83 On Chip Peripheral Components Figure 7 33 a Timer 2 Block Diagram ...
Page 215: ...Device Specifications Semiconductor Group 215 ...
Page 217: ...Device Specifications Semiconductor Group 217 Pin Configuration P LCC 68 ...
Page 219: ...Device Specifications Semiconductor Group 219 Logic Symbol ...
Page 226: ...Device Specifications Semiconductor Group 226 Figure 1 Block Diagram ...
Page 229: ...Device Specifications Semiconductor Group 229 Figure 2 Memory Address Spaces ...
Page 239: ...Device Specifications Semiconductor Group 239 Figure 4 Block Diagram of the A D Converter ...
Page 241: ...Device Specifications Semiconductor Group 241 Figure 5 Interrupt Request Sources ...
Page 242: ...Device Specifications Semiconductor Group 242 Figure 6 Interrupt Priority Level Structure ...